Assembly Instructions

SAFETY INFORMATION
PREPARATION
ASSEMBLY INSTRUCTIONS
Please read and understand this entire manual before attempting to assemble, operate or install the product.
WARNING
Turn off electricity at main fuse box (or circuit breaker box) before beginning installation by removing fuse (or switching off
circuit breaker).
Be careful not to damage or cut the wire insulation (covering) during fixture installation. Do not permit wires to contact any
surface having a sharp edge. Doing so may damage or cut the wire insulation, which could cause serious injury or death from
electric shock.
CAUTION
All electrical connections must be in agreement with local codes, ordinances or the national electric code (NEC). Contact
your municipal building department to learn about your local codes, permits and/or inspections. If you do not have electrical
wiring experience, refer to a do-it-yourself wiring handbook or have your fixture installed by a qualified licensed electrician.
Risk of fire – most dwellings built before 1985 have supply wire rated for 140°F/60ºC. Consult a qualified electrician before
installation.
Do not exceed the recommended wattage. Refer to the re-lamping label on the light socket for maximum wattage.
Do not replace a bulb when electrical outlet switch is turned to the “ON” position.
Do not immerse your lamp in water; doing so will damage the wire.
Keep materials that burn easily away from lit bulbs.
This fixture is intended to be mounted at a minimum of 6' above ground level.
Before beginning assembly, installation or operation of product, make sure all parts are present. Compare parts with package
contents list and diagram on previous page. If any part is missing or damaged, do not attempt to assemble, install or operate the
product. Contact customer service for replacement parts.
Tools required for assembly (not included): screwdriver, phillips screwdriver, pliers, electrical tape, wire cutters,safety glasses,
ladder, wire stripper, caulk.
1. Unscrew the two cap nuts
(HH) from the support screw
(CC), remove the mounting
strip (AA) from the fixture
body (D), and keep the
two cap nuts (HH) and two
rubber washers (GG) for
later use.
Loosen the hex nuts (EE)
on the support screws (CC)
and adjust the support
screws (CC) so that they
extend long enough to
protrude through the canopy
of the fixture body (D), then
secure the support screws
(CC) in place using the hex
nuts (EE).
2.
Fasten the mounting
strip (AA) onto the outlet
box using two outlet box
screws (short) (BB).
2
1 2
GG
AA
AA
FF
DD
CC
EE
HH
AA BB
D
D
3. Connect the black wire from the fixture body (D) to black wire from the
outlet box, the white wire from the fixture body (D) to white wire from the
outlet box, and the bare copper ground wire from the fixture body (D)
to ground wire from the outlet box. The bare copper ground wire from
the fixture body (D) must loop one turn under the head of green screw
(DD) on mounting strip (AA) before it is connected to the ground wire
from the outlet box. Cover the wires with wire connectors (FF). Tape the
wire connectors (FF) and wires together, and carefully position all wires
inside the outlet box.
3