Datasheet
PatchSee
Page 2 sur 2 Modified : 2005-11-27
Technical Data Sheet
Construction
Number of pairs
4
Conductor
Stranded bare copper wire
Gage
26 AWG
Insulation
Foam Skin Polyethylene
Pair screen
Al-laminated metal foil
Optical wave guide
2 POF 0.5 mm
Drain
Stranded drain wire tinned
Jacket
PVC Black with white printing
Overall diameter
5.8 mm
Plug housing
UL 1863 Polycarbonate
Contacts
Moved contacts
Contact Plating
50 µ inches gold minimum (1.2 µm)
Shielding
Tin-plated
Mechanical Properties of the cable
Fire Propagation Test Temperature range
During operation
Fire load Bending radius
UL 444 VW 1 Flame
test
-20°C up to +75°C 372 MJ/km >25 mm without load
Electrical Properties of the cable (at 20°C +/- 5°C)
DC loop
resistance
Insulation
resistance
(500V)
Capacitance
at 800 Hz
Impedance
1-100MHz
Impedance
100-
250MHz
Propagation
delay
Test
voltage
(DC, 1
min)
< 340Ω/km > 2000
MΩ*km
Nom.
43nF/km
100 +/- 15 Ω
NA < 427 ns/100m
1000 V