Environmental Declaration

PEP ecopassport No LGRP-00811-V01.01-EN Page 5 / 6
Legrand North and Central America
Pass & Seymour
50 Boyd Ave
Syracuse, NY 13209
1.877.BY.LEGRAND (295.3472)
www.legrand.us
Product Environmental Profile
Pass & Seymour: Turnlok® Locking
Connectors - 20/30A
ENVIRONMENTAL IMPACTS continued
For products covered by the PEP other than the Reference Product, the environmental impacts of each phase of the lifecycle can be
calculated with the following rules:
Manufacturing – The different amperage ratings and wire numbers across the product range lead to different amounts of plastic and
metal materials in the connectors. Those differences have variable effects on the environmental impacts in this phase. In the table
below, conversion factors are listed for each of the 11 indicators for each of the amperage-wire combinations that when multiplied by the
corresponding impacts of the Reference Product give the impacts of the desired product.
Distribution – The impacts in this phase are proportional to the mass of the product (including packaging) for all indicators. (Masses are
given in the constituent materials section of this document).
Installation – The impacts in this phase are equivalent across all products for all indicators.
Use – The different amperage ratings and pole numbers across the product range lead to different amounts of energy loss due to internal
resistance. In the table below, conversion factors are given for each of the amperage-pole combinations that when multiplied by the
corresponding impacts of the Reference Product give the impacts of the desired product. These conversion factors apply to all indicators.
End-of-Life – The different amperage ratings and wire numbers across the product range lead to different amounts of plastic and metal
materials in the connectors. In the table below, conversion factors are given for each of the amperage-wire combinations that when
multiplied by the corresponding impacts of the Reference Product give the impacts of the desired product. These conversion factors apply to
all indicators.
Indicator
20A 30A
2P3W; 3P3W 3P4W; 4P4W 4P5W 2P3W; 3P3W 3P4W; 4P4W 4P5W
GW 0.91 0.97 0.95 0.97 1.00 1.03
OD 0.78 1.00 0.98 0.90 1.00 1.17
A 0.93 1.13 1.01 0.97 1.00 1.04
WE 0.93 0.96 0.97 0.97 1.00 1.02
POCP 0.95 1.16 0.98 0.98 1.00 1.02
ADPe 0.49 0.65 1.03 0.75 1.00 1.45
PE 0.97 1.11 1.02 0.97 1.00 1.03
FW 0.77 0.87 1.02 0.89 1.00 1.21
ADPf 0.87 0.99 0.99 0.94 1.00 1.09
WP 0.93 0.92 0.92 0.98 1.00 1.00
AP 0.58 0.73 1.03 0.79 1.00 1.36
Indicator
20A 30A
2P3W 3P3W; 3P4W 4P4W; 4P5W 2P3W 3P3W; 3P4W 4P4W; 4P5W
All 0.30 0.44 0.59 0.67 1.00 1.33
Indicator
20A 30A
2P3W; 3P3W 3P4W; 4P4W 4P5W 2P3W; 3P3W 3P4W; 4P4W 4P5W
All 0.91 0.92 0.95 0.97 1.00 1.04