Compatibility Chart

Place tetraGRIP
fasteners from 3/8 in. to 1 in. from
the edge of the HardiePanel
®
vertical siding
Place tetraGRIP
fastener every 12 in. x 12 in. (Provides
Vasd
1
= 91 mph / Vult
2
= 118 mph for Exposure Category C
at 30 ft. mean roof height)
Place tetraGRIP
fasteners from 3/8 in. to 1 in. from the edge of
the HardieShingle
®
siding
Place a tetraGRIP
fastener every 16 in. o.c. (Provides Vasd
1
= 95
mph / Vult
2
= 123 mph for Exposure Category C at 30 ft. mean roof
height)
12in max
Fastener
12in max
96in
48in
3/8 - 1 in
2 in2 in
2 in2 in
Leave a min. lap of
1 1/2 in. between keyways
in successive course
3/8 - 1 in
16in
48in
Place the tetraGRIP
fastener 1 in. from top edge and 3/8 in. - 1 1/2
in. from the ends of the HardiePlank lap siding
Place a tetraGRIP
fastener every 16 in. o.c. (8.25 in. HardiePlank
siding: Provides Vasd
1
= 101 mph / Vult
2
= 130 mph for Exposure
Category C at 30 ft. mean roof height)
Space butt joints a minimum of 6 in. apart
1 in.
3/8 in. -
1 1/2 in.
THE BASICS
PSI
100 120
Maintain the compressor outlet air
pressure between 100psi and 120psi
Drive tetraGRIP
Studless Siding Fasteners flush
with the face of the plank, panel, or shingle
If nail is countersunk, fill nail hole and add a nail
snug
Contact your local Paslode sales representative to learn more.
© 2017 James Hardie Building Products Inc. All Rights Reserved. TM, SM, and ® denote trademarks or registered trademarks of James Hardie Technology Limited.
The Paslode and TetraGrip marks are trademarks of Illinois Tool Works Inc. 04/23
6 in.
IMPORTANT: This document is not intended to take the place of James Hardie published
installation instructions. Failure to follow James Hardie written installation instructions
and comply with applicable building codes may violate local laws, affect building envelope
performance and may affect warranty coverage. Failure to comply with all health and safety
regulations when cutting and installing this product may result in personal injury. Before
installation, confirm you are using the correct HardieZone® product instructions by visiting
hardiezone.com or call 1-866-942-7343 (866-9-HARDIE).
If you are a specifier or other responsible party for a project, ensure the information in these
specifications is appropriate for the application you are planning and that you undertake specific
design and detailing for areas which fall outside the scope of these specifications.
The following are fastener spacing examples for moderate basic wind speeds. For complete wind design loads please refer to ESR-2290 and
ESR-1844 at jameshardiepros.com
Countersunk,
Fill & Add Nail
1
Vasd = nominal design wind speed, ASCE 7-05, Wall Zone 5, 2009 IBC, 2009 & 2012 IRC, Exposure Category
C at 30 ft. mean roof height.
2
Vult = ultimate design wind speed, ASCE 7-10, Wall Zone 5, 2012 & 2015 IBC, 2015 IRC, Risk Category ll,
Exposure Category C at 30 ft. mean roof height.