User's Manual
97
012-05892A AC/DC Electronics Laboratory
®
11
Put alligator clips on the banana plugs of both Voltage Sensors. Connect the black alligator clip
of the Voltage Sensor in Analog Channel A to the component spring at the top end of the 22 kΩ
resistor, and the red clip to the component spring at the bottom end.
12
Connect the red alligator clip of the Voltage Sensor in Analog Channel B to the component
spring at the top end of the 1 kΩ resistor, and the black clip to the component spring at the
bottom end.
PART IIIA: Data Recording – ±1.5 Volts
➀ Turn on the DC power supply and adjust its voltage output to exactly +5 Volts.
➁ Turn on the power switch on the back of the power amplifier.
➂ Click the “ON” button ( ) in the Signal Generator window.
➃ Click the “REC” button ( ) to begin recording data. Recording will stop automatically after
200 samples are measured.
• Run #1 will appear in the Data list in the Experiment Setup window.
➄ Click the “OFF” button ( ) in the Signal Generator window.
➅ Turn off the power switch on the back of the power amplifier. Turn off the DC power supply.