User Manual
MD-150M User Manual
7. “K2” (Choose want to use Key)
Controller send:
SOH
“S”
ID1 ID2
“K” “2”
STX
DATA
ETX BCC
USB Reader responds:
SOH
“s”
ID1 ID2
“K” “2”
STX
data
ETX BCC
Data description:
1. “DATA” should be compare with A,B Key, sector number you want to lock, just as
follow: Card type (1 byte) + Page/block number (2 bytes)
2. Card type should be entered as: “M” for Multi-Page.
3. The range of page/block number is different in different card type.
4. “K2” function can’t lock a block of EM4135 tag. (Must use “K9”)
5. Responded “data” value will be as following:
If “data” is “Y” means page/block is successfully locked.
If “data” is “N” means failed.
Function description:
1. Use this function to lock the data in specified page/block.
2. Warning! This action is not recoverable, no any unlock maybe perform, use with
extreme care!!!
Example:
Controller send:
SOH + "S01K2" + STX + "M07" + ETX + BCC
USB Reader responds:
SOH + "s01K2" + STX + "Y" + ETX + BCC
(“Y” means page/block is successfully locked)
USB Reader responds:
SOH + "s01K2" + STX + "N" + ETX + BCC
(“N” means failed)
- 13 -