User manual

Table Of Contents
V7.4.1.0 published on December 20, 2022 57
Finally, note that ANAFI Ai’s smart battery will only allow charge in ambient temperatures between +10 °C
and +45 °C, and that using ANAFI Ai in temperatures approaching 0 °C will reduce its flying time. To minimize
this slight drop in the smart battery’s capacity, keep your battery as warm as possible before starting a flight
in a cold environment: be aware that if the temperature of the core of the battery drops below 5 °C, it will
not power the drone.
If the behavior of your battery is not consistent with the elements contained in this section, and if you
cannot get it to power your ANAFI Ai, you must reset your battery: plug it to a power source with one
of the enclosed cables, then keep the battery’s power button pressed for 15 seconds (regardless of
the behavior of the LEDs), and release the button.
The battery’s LEDs flash quickly, one after the other, alternating green and red: the reset is successful.
Battery state of health
ANAFI Ai’s
FreeFlight 7 gives the status of the following battery caracteristics:
- the serial number
- the global voltage
- the cells voltage
- the temperature
- the total capacity
- the state of health
- the cycles
To access the Battery state of health interface from the dashboard of FreeFlight 7, tap the “Drone
information” box, and click on the “Battery” box on the bottom right of the screen.
Battery state of health interface