Data Sheet
Confidential
7 (13)
Created by :
Benjamin Renoncourt Erreur !
Source du renvoi
introuvable.
Reference
Erreur ! Source
du renvoi
introuvable.
Title
Datasheet ICU for McLaren
Revised by :
Date
Revision :
Status
Benjamin Renoncourt
2019-12-04
1.1
APPROVED
4 INTERFACES AND CONNECTORS
The following interfaces and connectors are considered.
4.1 ICU box
4.1.1 Main connector
Main CONNECTOR
CONNEC
REF
MOLEX
STAK50H-200506201
CONNEC
REF
MOLEX
STAK50H-200506201
A01
ENTERTAIN_AUDIO_FR_OUT_P
B01
DISP_5V
A02
ENTERTAIN_AUDIO_FR_OUT_N
B02
DISP_GND
A03
ENTERTAIN_AUDIO_RR_OUT_N
B03
VBATT safe
A04
ENTERTAIN_AUDIO_RR_OUT_P
B04
VBATT
A05
ENTERTAIN_AUDIO_RL_OUT_P
B05
FUEL_LEVEL_12V
A06
ENTERTAIN_AUDIO_RL_OUT_N
B06
FUEL_LEVEL_GND
A07
ENTERTAIN_AUDIO_FL_OUT_N
B07
GND safe
A08
ENTERTAIN_AUDIO_FL_OUT_P
B08
GND
A09
LIN
B09
SAFE_AUDIO_OUT_N
A10
LIN_12V
B10
SAFE_AUDIO_OUT_P
A11
LIN_GND
B11
DISP1_BCKL_ENABLE
A12
Cavity Closed
B12
Cavity Closed
A13
LINE_IN_R_SIGNAL_IN
B13
MIC1_GND
A14
LINE_IN_L_SIGNAL_IN
B14
MIC1_SIGNAL_IN
A15
LINE_IN_DETECT
B15
MIC2_GND
A16
LINE_IN_GND
B16
MIC2_SIGNAL_IN
A17
DISP3_BCKL_ENABLE
B17
CAN1_H
A18
DISP3_INT
B18
CAN1_L
A19
Cavity Closed
B19
Cavity Closed