DC MANAGEMENT
bluesea.com
ATO
®
or ATC
®
In-Line Fuse Holders
In-Line
Supplied with 12 AWG pigtails
30A Max fuse amperage
Fuse sold separately (page 40)
Waterproof In-Line
Supplied with 12 AWG pigtails
30A Max fuse amperage
Fuse sold separately (page 40)
ANL Fuses
For 35A to 750A
circuit protection
Silver-plated connector
blades for corrosion resistance
Visible indication of blown condition
Specications
Interrupting Capacity 6,000A @ 32V DC
Voltage Maximum Operating 32V DC
Trip Time Delay See bluesea.com
Regulatory
35-500A ONLY—Meets SAE J1171 external ignition protection
requirements
Class T Fuses
High interrupt capacity for
large battery banks including
Lithium-Ion and TPPL batteries
Extremely fast short-circuit response
Recommended by most inverter manufacturers
Specications
Interrupting Capacity 20,000A @ 160V DC
Voltage Max Operating 160V DC
Trip Time Delay See bluesea.com
Regulatory
UL listed to standard 248-15
AGC
®
In-Line Fuse Holders
Crimpable In-Line
Accepts 12–16 AWG wire
30A Max fuse amperage
Fuse sold separately (page 40)
Waterproof In-Line
Accepts 12–18 AWG wire
30A Max fuse amperage
Fuse sold separately (page 40)
Heavy Duty In-Line
Supplied with tinned copper
12 AWG pigtails
30A Max fuse amperage
Fuse sold separately (page 40)
5060-BSS
5061-BSS
5063-BSS
5064-BSS
Part # Amps Retail Pack
5164-BSS 35A 1
5165-BSS 40A 1
5122-BSS 50A 1
5123-BSS 60A 1
5124-BSS 80A 1
5125-BSS 100A 1
5126-BSS 130A 1
5127-BSS 150A 1
5128-BSS 175A 1
Part # Amps Retail Pack
5129-BSS 200A 1
5131-BSS 250A 1
5133-BSS 300A 1
5135-BSS 350A 1
5136-BSS 400A 1
5137-BSS 500A 1
5161-BSS 600A 1
5163-BSS 750A 1
Part # Amps Retail Pack
5117-BSS 225A 1
5118-BSS 250A 1
5119-BSS 300A 1
Part # Amps Retail Pack
5120-BSS 350A 1
5121-BSS 400A 1
5065-BSS
Terminal Fuses
MRBF—Marine Rated Battery Fuse
Space-saving ignition protected fuse
for 30 to 300 Amp loads. Must use
with Terminal Fuse Block (page 42)
Color-coded for easy identication
Visible indication of blown condition
Specications
Interrupting Capacity 10,000A @ 14V DC
5,000A @ 32V DC
2,000A @ 58V DC
Voltage Max Operating 58V DC
Fuse Hole Opening M8 (5/16")
Trip Time Delay See bluesea.com
Regulatory
Meets SAE J1171 external ignition protection requirements
IP66—protected against powerful water jets
ABYC E-11.10.1.1.1. Overcurrent Protection Device Location—
Ungrounded conductors shall be provided with overcurrent protection
within a distance of seven inches (175mm) of the point at which the
conductor is connected to the source of power measured along
the conductor
Part # Amps Color Retail Pack
5175-BSS 30A LT Green 1
5176-BSS 40A LT Blue 1
5177-BSS 50A Red 1
5178-BSS 60A Gold 1
5180-BSS 75A Brown 1
5181-BSS 80A Lime 1
5182-BSS 90A Purple 1
5183-BSS 100A Yellow 1
5184-BSS 125A Green 1
5185-BSS 150A Orange 1
5186-BSS 175A White 1
5187-BSS 200A Blue 1
5189-BSS 250A Pink 1
5190-BSS 300A Gray 1