Full Product Manual

64
TEST & MEASURE
park-power.com
IRT200 Range
Temperature Range (-67 to 482°F) -55 to 250°C
Emissivity Fixed
Laser Sighting
3
Lock Mode
Low Battery Indicator
3
Backlit Display
3
Auto O
3
Temp Check™ Gun Style Infrared Thermometer
8:1 Distance to spot ratio
Laser sighting for accurate results
Backlit display for low light applications
Min/Max function to hold either minimum reading or maximum reading on
the display in Max mode
Auto power o
IRT200
IRT100 Range
Temperature Range (-31 to 689°F) -35 to 365°C
Emissivity Fixed
Laser Sighting
3
Lock Mode
3
Low Battery Indicator
3
Backlit Display
Auto O
3
Temp Check™ Pocket Style Infrared Thermometer
6:1 distance to spot ratio
Toggle between Celsius and Fahrenheit
Laser sighting for accurate results
Min/Max function to hold either minimum reading or maximum reading on
the display min/max mode
Auto power o
Wrist lanyard for increased handling
IRT100
Non-contact Temperature Measurement
Safety is the number one priority on any job site. Any test unit that
can be used to measure or review an application without coming in
contact with a live conductor is a necessity. The IR Thermometers allow
for critical temperature measurements to be taken without having to
touch an energized circuit. The D:S ratio, or distance to spot ratio, is a
rating used state the distance, in feet, that the test unit should be from
the target in order to measure a one foot diameter section. In other
words, a 6:1 D:S Ratio means that from six feet away, the test unit is
measuring a one foot diameter section of the target.
TECH tip