Swing out design allows replacement of the fuse without removing
fasteners
Accepts 5/16" (M8) ring terminals
Clear insulating cover breakouts allow wire access in any direction
Insert molded studs ensure secure fuse mounting
Stainless steel studs provide resistance to corrosion and high torque
One-piece stainless ange nuts ensure safe and secure connections
UL 94-V0 base resists high heat
Fuse sold separately (page 41)
Specications
Voltage Max Operating 32V DC
Amperage Max Operating 750A
Terminal Stud Size 5/16"–18 (M8)
Cable Size Up to 4/0 AWG
Fuse Mounting Blocks Tin-Plated Copper
ANL Fuses Available 35–750 Amps
ANL
®
Fuse Blocks
Accepts a wide range of ANL fuse amperages
for versatile fusing
Part # Terminal Stud Mounting
5503-BSS 5/16"-18 (M8) 1/4" (M6) Screws
5005-BSS
Four stud design provides ample access around connecting stud to
install large cable lugs without obstruction from the fuse
Accepts 3/8" (M10) ring terminals
Clear insulating cover breakouts allow wire access in any direction
Insert molded studs ensure secure fuse mounting
Stainless steel studs provide resistance to corrosion and high torque
One-piece stainless ange nuts ensure safe and secure connections
UL 94-V0 base resists high heat
Fuse sold separately (page 41)
Specications
Voltage Max Operating 160V DC
Amperage Max Operating 400A
Cable Size Up to 4/0AWG (120 mm²)
Fuse Mounting Blocks Tin-Plated Copper
Class T Fuses available 225–400 Amps
Class T Fuse Block
Allows use of Class T fuses for fast acting circuit
protection of inverters
5502-BSS
Part # Terminal Stud Mounting
5502-BSS 3/8"-16 (M10) 1/4" (M6) Screws
285 Series Circuit Breakers
When switching and circuit
protection are both required
Visible yellow reset lever shows
open condition
Trip-free design cannot be
held closed after trip
Surface mount
Specications
Interrupting Capacity 3,000A @ 48V DC
Voltage Max Operating 48V DC
Type Thermal
Class Type III—Switchable
Manual Reset—Trip Free
Terminal Stud M6 (accepts 1/4" Ring Terminal)
Terminal Stud Torque 50 in-lb (7.9 Nm)
Mounting Hole Accepts 1/4" screw (M6)
Regulatory
CE marked, Meets SAE J1171 external ignition protection
requirements
IP67—protected against immersion up to 1 meter for 30 minutes
7187-BSS
Part # Amps
7180-BSS 25A DC
7181-BSS 30A DC
7182-BSS 40A DC
7183-BSS 50A DC
Part # Amps
7184-BSS 60A DC
7185-BSS 70A DC
7186-BSS 80A DC
7187-BSS 100A DC
Part # Amps
7188-BSS 120A DC
7189-BSS 150A DC
Appropriate for DC Main
and inverter circuit
protection applications
Weatherproof—ideal for
towables or anywhere there
may be partial exposure
to the elements
Insulating cap prevents
accidental shorts
Fuses sold separately
(page 41)
Specications
Voltage Max Operating 58V DC
Amperage Max Operating 300A
Terminal Fuses Available 30–300 Amps
Regulatory
Meets SAE J1171 external ignition
protection requirements
Terminal Fuse Blocks
MRBF—Marine Rated Battery Fuse
Designed specically to
mount on a 3/8" battery post,
battery switch, or bus bar
Part # Terminal Stud Size
Mounting
Hole Fuses
5191-BSS M8 (5/16"–18) 3/8" 1
2151-BSS M8 (5/16"–18) 3/8" 2
2151-BSS
5191-BSS