1. Series HX Compressed Air Filters
Parker’s HX-Series lters represent the most advanced coalescing lter technologies of today. Due to the breadth of
this series product line, they are very versatile and the types of applications they will work in is nearly limitless.
The lters are offered with ve basic types of lter media:
Fine Coalescers: Remove liquid and tiny solid contaminants from compressed air. Types 4C, 6C, XF
Bulk or Pre-coalescers: Remove large quantities of liquid contaminants / tiny solids. Types 7CP, 8C, 10C
Water Separator: Remove bulk liquids from compressed air. Type WS
Particulate: Remove larger solid contaminants from compressed air. Type 3P
Adsorber: Remove oil vapor from compressed air. Type A
The lters are supplied with either manual drains or auto drains as well as differential pressure gauges or plugged
gauge ports. Differential pressure gauges are standard on lters beginning with bowl size “C” and larger. They are
optional on “B and BH” sizes. See 2.1 below for part number breakdown.
All HX-Series lters are designed to minimize operating differential pressure which will result in low operating costs. A
number of innovations in both housing design and lter element design combine to result in low energy consumption
and operating costs. They are detailed in the HX-Series general brochure. See Section 9 for accessories.
1.1 Scope of Delivery
These lters are supplied in a ready to operate condition and can be installed directly into the compressed
air system. Some of the accessories mentioned later in this manual are supplied in separate packages and
should be installed according to their own instruction sheets.
2. Product Identification / Part Number Breakdown
2.1 HX Series Filter Assemblies
HX 6CN 3 C Y
Series Thread Conn. Bowl Size Element Type Accessories
HX N-NPT 1 = 1/4” A 4C N = No Accessories, Manual Drain
15 = 3/8” B 6C A = Auto Drain
2 = 1/2” B, BH 8C G = Diff. Pressure Gauge
3 = 3/4” BH, C 10C Y = Auto Drain and Diff. Pressure Gauge
4 = 1” C, D 7CP Note:
G and Y options not available
on HXN1A versions.
5 = 1-1/4” D, E XF
6 = 1-1/2” D, E WS
8 = 2” E, F, G 3P
10 = 2-1/2” H A
12 = 3” H, J
Examples: HXN1A-6CN, HXN2BH-WSA, HXN12J-XFX, HXN8G-6CG