Brochure

Any compressor with aftercooler, 2-stage coalescing and refrigerated dryer. Air intended for use with air-gauging, air conveyors,
spray-painting, food processing, instrumentation, blow molding, cosmetics, lm processing, bottling, pharmaceuticals, dairy,
breweries, medical, robotics and close tolerance valves.
SPECS MET: CGA – G7.1 (Grades D & E), ISAS7.3 Fed. Std. 209 (Class 100)
100° F
Aftercooler
Use media
grade 6C, XF, 7CP
Compressor Room (Source)
Air Preparation Equipment:
Auto
Drain
Refrigerated
Dryer
Compressor
50 PSIG
Dew Point
40° F
Use media
grade 6C, XF
Point-Of-Use
Air Preparation Equipment:
Regulator
Auto
Drain
ISO Class 1 4 2
Any compressor with aftercooler, 2-stage coalescing, refrigerated dryer and carbon absorber. Air intended for use as industrial
breathing air and decompression chambers. CAUTION: Always use high temperature synthetic lubricants and monitor (alarm for
carbon monoxide concentrations). This system will not eliminate toxic gases!
OTHER SPECS MET: O.S.H.A. 29CFR 1910.134
ISO Class 1 4 1
50 PSIG
100° F
Dew Point
40° F
Aftercooler
Use media
grade 6C, XF
Use media
grade A
Use media
grade 6C, XF, 7CP
Compressor Room (Source)
Air Preparation Equipment:
Point-Of-Use
Air Preparation Equipment:
Regulator
Auto
Drain
Auto
Drain
Refrigerated
Dryer
Compressor
Any compressor with aftercooler, two-stage and double coalescing regenerative-type desiccant dryer and a carbon adsorber.
Air intended for use in applications involving rapid expansion of compressed air, critical instrumentation, high purity gases,
automotive paint systems, etc. CAUTION: This air is too dry for respiratory use.
ISO Class 1 2 1
Use media
grade 6C, XF
For Heat Generated
Dryers, Consult Factory
Dust
Catching
Housing
50 PSIG
Dew Point
40° F
Use media
grade 6C, XF
Use media
grade A
Point-Of-Use
Air Preparation Equipment:
Regulator
Auto
Drain