Spec Sheet
10
Correction Factors
TemperatureCorrectionFactorCFT
MaximumInlet
Temperature
°C 25 30 35 40 45 50
°F 77 86 95 104 113 122
CFT 1.00 1.00 1.00 1.04 1.14 1.37
PressureCorrectionFactorCFP
MinimumInlet
Pressure
barg 4 5 6 7 8 9 10 11 12
psig 58 73 87 102 116 131 145 160 174
CFP 1.60 1.33 1.14 1.00 1.03 0.93 0.85 0.78 0.71
DewpointCorrectionFactorCFD
Standard Option1
Required
Dewpoint
PDP°C -40 -70
PDP°F -40 -100
CFD 1.00 1.43
Model
FilterPipeSize
BSPTorNPT
InletGeneral
PurposePre-filter
InletHigh
EfficiencyFilter
Outlet
DustFilter
DAS1
3
/
8"
AO005B FX
Built into dryer Built into dryer
DAS2
3
/
8"
AO005B FX
DAS3
3
/
8"
AO005B FX
DAS4
3
/
8"
AO005B FX
DAS5
3
/
8"
AO005B FX
DAS6
3
/
8"
AO0010B FX
DAS7
3
/
8"
AO0010B FX
Weights and Dimensions
Model
Pipe
Size
Dimensions
Weight
Height(H) Width(W) Depth(D)
mm ins mm ins mm ins Kg lbs
DAS1
3
/
8" 422 16.6 289 11.4 149 5.9 11 24.2
DAS2
3
/
8" 500 19.7 289 11.4 149 5.9 13 28.7
DAS3
3
/
8" 616 24.2 289 11.4 149 5.9 16 35.3
DAS4
3
/
8" 692 27.2 289 11.4 149 5.9 18 39.7
DAS5
3
/
8" 847 33.3 289 11.4 149 5.9 20 44.1
DAS6
3
/
8" 906 35.7 289 11.4 149 5.9 23 50.7
DAS7
3
/
8" 1098 43.2 289 11.4 149 5.9 28 61.7
*MiDAS dryers include integral high efficiency pre and general purpose dust filters.
= G (BSPP) or N (NPT)
Recommended Filtration
W D
H
DAS1-7