Compressor room
1
Air Compressor
2
Wet
Air Receiver
3
Condensate Drain
4
Water Separator
5
Coalescing Filters
6
Modular Adsorption Dryer
7
Dust Filter
8
Condensate Drainage
9
Oil / Water Separator
10
Dry Air Receiver
11
Oil Vapour Removal
12
Sterile Air Filter
13
On-site Nitrogen Gas Generator
14
Point of use Adsorption Dryer
15
Breathing Air Purifier
Key
7
Selecting the right dryer for
your compressed air system
To achieve the degree of air quality specified by ISO8573-1:2010,
a careful approach to system design, commissioning and
operation must be adopted.
Parkerdomnickhunterrecommendsthatcompressedairistreated:
•Priortoentryintothedistributionsystem
•Atcriticalusagepointsandapplications
Thisensuresthatcontaminationalreadyinthedistributionsystemisremoved.
Purification equipment should be installed where the air is at the lowest possible
temperature (i.e. downstream of after-coolers and air receivers). Point-of-use
purification equipment should be installed as close as possible to the application.