Brochure

17
Dryer performance
DryerModels
Dewpoint
(Standard)
ISO8573-1:2010
Classification
(standard)
Dewpoint
(Option1)
ISO8573-1:2010
Classification
(Option1)
Dewpoint
(Option2)
ISO8573-1:2010
Classification
(Option2)
ºC ºF
ºC ºF ºC ºF
MXLE -40 -40 Class 2 -70 -100 Class 1 -20 -4 Class 3
PNEUDRI MXLE ADVANTAGE
Technical data
SingleBank
Model PipeSize
Flowrates
L/s m
3
/min m
3
/hr cfm
MXLE102C G 2 113 6.81 408 240
MXLE103C G 2 170 10.22 612 360
MXLE103 G 2 213 12.78 765 450
MXLE104 G 2 283 17.03 1020 600
MXLE105 G 2
1
/
2 354 21 1275 750
MXLE106 G 2
1
/
2 425 26 1530 900
MXLE107 G 2
1
/
2 496 30 1785 1050
MXLE108 G 2
1
/
2 567 34 2040 1200
Product Selection
Stated flows are for operation at 7 bar g (100 psi g) with reference to 20°C, 1 bar a, 0% relative water vapour pressure.
For flows at other pressures apply the correction factors shown.
* ISO8573-1 Classifications when used with included Parker domnick hunter OIL-X EVOLUTION pre / post filtration
Dryer
Models
Min
Operating
Pressure
Max
Operating
Pressure
Min
Operating
Temp
Max
Operating
Temp
Max
Ambient
Temp
Electricalsupply
(standard)
Electrical
supply
(optional)
Thread
Connections
Noise
Level
barg psig barg psig °C °F °C °F °C °F dB(A)
MXLE 5 58 13 190 5 41 50 122 55 131
380V - 420V 3PH 50Hz
440V - 480V 3PH 60Hz
N/A BSPP <75
Model MXLE102c MXLE103c MXLE103 MXLE104 MXLE105 MXLE106 MXLE107 MXLE108
Vacuum
PumpkW
50Hz 3 3 4 5.5 7.5 8 9.5 11
60Hz 3.6 3.6 4.8 6.6 9 9.6 11.4 13.2
Correction Factors
TemperatureCorrectionFactorCFT
MaximumInlet
Temperature
°C 25 30 35 40 45 50
°F 77 86 95 104 113 122
CFT 1.00 1.00 1.00 1.04 1.14 1.37
DewpointCorrectionFactorCFD
Option2 Standard Option1
Required
Dewpoint
PDP°C -20 -40 -70
PDP°F -4 -40 -100
CFD 0.91 1.00 1.43
PressureCorrectionFactorCFP
Minimum
InletPressure
barg 4 5 6 7 8 9 10 11 12 13
psig 58 73 87 100 116 131 145 160 174 189
CFP 1.60 1.33 1.14 1.00 0.89 0.80 0.73 0.67 0.62 0.57