Brochure
14
Correction Factors
TemperatureCorrectionFactorCFT
MaximumInlet
Temperature
°C 25 30 35 40 45 50
°F 77 86 95 104 113 122
CFT 1.00 1.00 1.00 1.04 1.14 1.37
PressureCorrectionFactorCFP
Minimum
InletPressure
barg 4 5 6 7 8 9 10 11 12 13
psig 58 73 87 100 116 131 145 160 174 189
CFP 1.60 1.33 1.14 1.00 0.89 0.80 0.73 0.67 0.62 0.57
Weights and Dimensions
Dryer Coding Example
DRYER
MODEL
CONTROLLER
TYPE
NUMBEROF
DRYINGBANKS
NUMBEROF
DRYINGCOLUMNS
MX
S = Smart
A = Advanced
No of individual
dryers in installation
Number of columns
per dryer bank
MX S 3 08
DS = DDS Fitted
(DDS standard with
Advanced Controllers)
DS
DDSENERGY
MANAGEMENT
Example: PNEUDRI model MXS308DS
Model
Pipe
Size
Dimensions
Weight
Height(H) Width(W) Depth(D)
mm ins mm ins mm ins kg lbs
MX
102C
2" 1647 64.8 687 27.0 550 21.7 235 518
MX
103C
2" 1647 64.8 856 33.7 550 21.7 316 696
MX
103
2" 1892 74.5 856 33.7 550 21.7 355 782
MX
104
2" 1892 74.5 1025 40.3 550 21.7 450 992
MX
105
2
1
/
2" 1892 74.5 1194 47.0 550 21.7 543 1197
MX
106
2
1
/
2" 1892 74.5 1363 53.6 550 21.7 637 1404
MX
107
2
1
/
2" 1892 74.5 1532 60.3 550 21.7 731 1611
MX
108
2
1
/
2" 1892 74.5 1701 67.0 550 21.7 825 1818
Recommended Filtration
ForDryer
Model
Filter
PipeSize
BSPTorNPT
Inlet
GeneralPurpose
Pre-filter
Inlet
HighEfficiency
Filter
Outlet
DustFilter
MX
102C
2"
AO040H FX AA040H FX AR040H MX
MX
103C
2"
AO040H FX AA040H FX AR040H MX
MX
103
2"
AO045H FX AA045H FX AR045H MX
MX
104
2"
AO045H FX AA045H FX AR045H MX
MX
105
2
1
/
2"
AO050I
FX AA050I FX AR050I MX
MX
106
2
1
/
2"
AO055I
FX AA055I FX AR055I MX
MX
107
2
1
/
2"
AO055I
FX AA055I FX AR055I MX
MX
108
2
1
/
2"
AO055I
FX AA055I FX AR055I MX
= G (BSPP) or N (NPT)
DewpointCorrectionFactorCFD
Option2 Standard Option1
Required
Dewpoint
PDP°C -20 -40 -70
PDP°F -4 -40 -100
CFD 0.91 1.00 1.43
D W
H
MX 102c - 108