Brochure

13
Dryer Performance
DryerModels
Dewpoint
(Standard)
ISO8573-1:2010
Classification
(standard)
Dewpoint
(Option1)
ISO8573-1:2010
Classification
(Option1)
Dewpoint
(Option2)
ISO8573-1:2010
Classification
(Option2)
ºC ºF ºC ºF ºC ºF
MX
-40 -40 Class 2 -70 -100 Class 1 -20 -4 Class 3
MXP* -40 -40 Class 2 -70 -100 Class 1 -20 -4 Class 3
PNEUDRI MX
Technical Data
Dryer
Models
Min
Operating
Pressure
Max
Operating
Pressure
Min
Operating
Temp
Max
Operating
Temp
Max
Ambient
Temp
Electricalsupply
(standard
Electrical
supply
(optional)
Thread
Connections
Noise
Level
barg psig barg psig °C °F °C °F °C °F dB(A)
MXS 4 58 13 190 5 41 50 122 55 131
85 - 265 V
1ph 50/60Hz
N/A
BSPP
or NPT
<75
MXA 4 58 13 190 5 41 50 122 55 131
85 - 265 V
1ph 50/60Hz
N/A
BSPP
or NPT
<75
MXP* 4 58 13 190 5 41 50 122 55 131 N/A N/A
BSPP
or NPT
<75
SingleBank
Model PipeSize
Flowrates
L/s m
3
/min m
3
/hr cfm
MX
102C
2" 113 6.81 408 240
MX 103C
2" 170 10.22 612 360
MX 103
2" 213 12.78 765 450
MX 104
2" 283 17.03 1020 600
MX 105
2
1
/
2" 354 21 1275 750
MX 106
2
1
/
2" 425 26 1530 900
MX 107
2
1
/
2" 496 30 1785 1050
MX 108
2
1
/
2" 567 34 2040 1200
Multi-Bank
2xMX 105
2
1
/
2" 708 43 2550 1500
2xMX 106
2
1
/
2" 850 51 3060 1800
2xMX 107
2
1
/
2" 992 60 3570 2100
2xMX 108
2
1
/
2" 1133 68 4080 2400
3xMX 106
2
1
/
2" 1275 77 4590 2700
3xMX 107
2
1
/
2" 1488 89 5355 3150
3xMX 108
G 2
1
/
2 1700 102 6120 3600
Product Selection
Stated flows are for operation at 7 bar g (100 psi g) with reference to 20°C, 1 bar a, 0% relative water vapour pressure.
For flows at other pressures apply the correction factors shown.
Controller Options
Controller
Options
Function
Poweron
Indication
Fault
Indication
DisplayFault
Condition
Values
Service
Interval
Indication
Service
Countdown
Timers
Comfigurable
Alarm
Settings
RemoteVolt
FreeAlarm
Contacts
Filter
Service
Timer
DDSEnergy
Management
System
SMART
SMARTDDS
ADVANCED
*ATEX compliant option available.
For hazardous environments , a fully pneumatic ATEX compliant
version of PNEUDRI is available.
ATEX Directive 94/9/EC
Group II, Category 2GD, T6.