Brochure

11
Dryer Performance
DryerModels
Dewpoint(Standard)
ISO8573-1:2010
Classification(standard)
Dewpoint(Option1)
ISO8573-1:2010
Classification(Option1)
ºC ºF ºC ºF
DME -40 -40 Class 2 -70 -100 Class 1
DMP* -40 -40 Class 2 -70 -100 Class 1
Technical Data
DryerModels
MinOperating
Pressure
MaxOperating
Pressure
MinOperating
Temperature
MaxOperating
Temperature
MaxAmbient
Temperature
Electrical
Supply
(Standard)
Electrical
Supply
(Optional)
Thread
Connection
Noise
Level
barg psig barg psig °C °F °C °F °C °F dB(A)
DME012-DME040 4 58 16 232 5 41 50 122 55 131
230V 1ph
50/60Hz
110V 1ph
50/60Hz
BSPP or NPT <75
DME050-DME080 4 58 13 190 5 41 50 122 55 131
230V 1ph
50/60Hz
110V 1ph
50/60Hz
BSPP or NPT <75
DMP12P-DMP80P* 4 58 10.5 152 5 41 50 122 55 131 FULLY PNEUMATIC BSPP or NPT <75
ControllerOptions
Function
PowerOn
Indication
Fault
Indication
DisplayFault
Condition
Values
Service
Interval
Indication
Service
Contdown
Timers
Congurable
Alarm
Settings
RemoteVolt
FreeAlarm
contacts
Filter
Service
Timer
DDSEnergy
Management
System
DME
(Electroniccontrol)
DMEDDS
Controller Options
PNEUDRI MIDIplus
Stated flows are for operation at 7 bar g (100 psi g) with reference to 20°C, 1 bar a, 0% relative water vapour pressure.
For flows at other pressures, apply the correction factors shown.
Product Selection
Model PipeSize
InletFlowrates
L/S m
3
/min m
3
/hr cfm
DME012
3
/
4" 11" 0.68 41 24
DME015
3
/
4" 15 0.91 55 32
DME020
3
/
4" 20 1.19 71 42
DME025
3
/
4" 25 1.50 90 53
DME030
3
/
4" 31 1.84 110 65
DME040
3
/
4" 42 2.49 149 88
DME050 1" 50 3.01 180 106
DME060 1" 61 3.69 221 130
DME080 1" 83 4.99 299 176
*ATEX compliant option available.
For hazardous environments, a fully pneumatic ATEX compliant
version of PNEUDRI is available.
ATEX Directive 94/9/EC
Group II, Category 2GD, T6.