Brochure

Table Of Contents
Catalog CIC-2003-1/US
Industrial Refrigeration Products: Liquid Level Control
Parker Hannifin Corporation
Climate & Industrial Controls Group
Cleveland, OH
427
Industrial
Refrigeration
Products
Depth Tracker Transducer Probes
How to Order
Probes can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that
represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Options
Hex Boss
Optional Probelok
Zero LED
Span LED
LCD Span Adjustment
LCD Zero Adjustment
Liquid Crystal Display
4-20mA Return Signal
12-36 Volts Input Voltage
Probe Span Adjustment
Probe Zero Adjustment
Display
Local Display
No Display
Remote Display
Display
Riser
Probelok
Probelok
Refer to Bulletin 61-30 for details
on installation and settings.
Weights
With Local With Remote
Length Less Display Display Display
kg lb kg lb kg lb
2 ft 2.7 6 1.9 4.2 2.1 4.7
3 ft 3.2 7 2.3 5.0 2.5 5.5
4 ft 4.1 9 3.1 6.8 3.3 7.3
5 ft 5.2 11.5 4.4 9.6 4.6 10.1
6 ft 5.7 12.5 4.7 10.5 4.9 11.0
7 ft 6.4 14 5.5 12 5.7 12.5
8 ft 6.8 15 5.9 13 6.1 13.5
10 ft 7.7 17 6.8 15 6.8 15.5
12 ft 8.6 19 7.7 17 7.9 17.5
Connection
N NPT (Standard)
P Probelok
Sleeve
C No Sleeve
S* Sleeve
* Not available on 10-12 ft.
Probe Length
02 2 feet
03 3 feet
04 4 feet
05 5 feet
06 6 feet
07 7 feet
08 8 feet
10 10 feet
12 12 feet
Display
N No Display
D Local Display
R Remote Display
Riser
X No Riser
R Riser
Length Type Display Sleeve Connection Riser
05 ITP D C N X
Technical Information and How to Order