Brochure

Table Of Contents
Parker Hannifin Corporation
Climate & Industrial Controls Group
Cleveland, OH
Catalog CIC-2003-1/US
Industrial Refrigeration Products: Liquid Level Control
426
Depth Tracker Transducer Probes
Description
The Depth Tracker Liquid Level Industrial Transducer Probe
(ITP) is used to provide a current signal proportional to the
vertical liquid level. A remote programmable controller
(PLLC) or microprocessor functioning as a switching
mechanism can convert the signal transmitted.
This device is for use with refrigerant R-717 (ammonia) only.
It may be used with liquid temperatures in a range of
-77° to 57° C (-107° to 135° F). The minimum ambient for
circuit board enclosure is -29°C (-20° F).
Probe lengths: 2, 3, 4, 5, 6, 7, 8, 10 & 12 feet
Integrated construction achieved by molding the PTFE
sleeve directly to the center rod
Electrical connection via 3/4 conduit boss or jacketed
communications cable of suitable temperature/moisture
protection
Fully potted circuit board
Local or remote digital read-out options
Optional display riser accommodates column insulation
Unique probelok connection option
Factory pre-calibrated for ammonia for 0-100% level
output in 4" IPS Standpipe. The electronics may be re-
calibrated in the field to permit viewing of liquid level over
any segment representing more than 40% of the probes
overall length.
All wetted parts are stainless steel construction to
prevent corrosion
Dimensions
Sight Glasses
Level Column
R/S
Standpipe
Cap
Weld
Globe Valve
w/Horizontal
Stem
Globe Valve
w/Horizontal
Stem
Weld
Optional Oil Drain
Allow for Insulation Space
102mm (4")
Min.
25.4mm (1")
100% Level
(From Factory)
Probe
Length
25.4mm (1")
Non-Sensing
Area of Probe
16mm (.625")
51mm
(2")
0% Level
(From Factory)
Minimum
Tube
Length*
*Minimum Tube Length = Probe Length + 60mm (2.375")
Probe with Local Display and Riser
Technical Information and Dimensions