Brochure

Table Of Contents
Catalog CIC-2003-1/US
Industrial Refrigeration Products: Gas Powered Suction Stop Valves
Parker Hannifin Corporation
Climate & Industrial Controls Group
Cleveland, OH
399
Industrial
Refrigeration
Products
Type CK5
How to Order
Type CK5 valves can be specified by using the symbols in the chart below to develop a model number. Select only those symbols
that represent the features desired, and place them in the sequence indicated by the example at the top of the chart.
Strainer
N No Strainer
S w/Strainer
Lens Color
0 No Pilot Light
G Green (std)
R Red
A Amber
W White
Port Inlet Outlet Pilot Pilot Coil Voltage, Pilot Lens
Size Type Flange Flange Connection Option Coil Style Light Color Strainer
NOTE: For sizes 125 and 150 only: Where pilot
solenoid valve is designated by this model code, its
companion flanges will be supplied to correspond
to pilot connection as selected within this model
number. Customer may designate pilot style “0”
and order S8F pilot solenoid valve separately.
Port Size
032 32mm (1¼")
040 40mm (1
5
/8")
050 50mm (2")
065 65mm (2½")
075 75mm (3")
100 100mm (4")
125 125mm (5")
150 150mm (6")
Flange Type Connection
X Less 00 None
Flanges
F FPT (IPS) 10 1¼"
S SW (IPS) 12 1½"
W Weld Neck (IPS) 16 2"
20 2½"
24 3"
32 4"
40 5"
48 6"
K ODS (US) 11 1
3
/8"
13 1
5
/8"
17 2
1
/8"
21 2
5
/8"
25 3
1
/8"
29 3
5
/8"
33 4
1
/8"
D DIN Weld Neck Enter size
from table
C EC-Br Copper below.
Not all flange types and sizes
are available for each port size.
See Flange Availability table
for allowable combinations.
050 CK5 F16 F16 F03 1 12 0 0 S
Flange Availability & Weights
Table shows flange size codes available by flange type for each port size code
Pilot Strainer Connection*
Flange Type Connection
F FPT (IPS) 02 ¼"
S SW (IPS) 03
3
/8"
W Weld Neck 04 ½"
(IPS) 06 ¾"
K ODS (US) 04 ½"
05
5
/8"
07
7
/8"
*Must be specified even if pilot
solenoid is not ordered.
FPT only.
Flange Connections Available Weight
Port
FPT (IPS)
Socket Weld (IPS)
ODS (US) DIN Weld Neck EC-Br Copper
Less Flanges With Flanges
Code Weld Neck (IPS) kg lb kg lb
032 10 12 10 12 11 13 17 32 40 50 30 36 42 13 28 15 33
040 12 16 12 16 13 17 21 40 50 25 55 28 60
050 12 16 12 16 13 17 21 40 50 25 55 28 60
065 20 21 25 65 75 34 74 36 79
075 24 25 29 75 47 104 50 109
100 32 33 A0 71 157 74 162
125 40 128 282 131 287
150 48 204 450 207 455
Remote Pilot Light
0 None
1 PLT-1 (NEMA 1)
2 PLT-2 (NEMA 4)
5 PLT-5
With coils 1, 3 & 8 only. See
page 376 for voltages.
Pilot Option
0* No Pilot Solenoid
1 With Pilot Solenoid
2* With Pilot Solenoid
and Strainer
* Available with 5" and 6" valves
only. See note below.
Coil Style (32-100mm)
0 No Coil or Housing
8 Compact C, D Operator
w/18" Leads
9 Compact C, D Operator
w/DIN Connector
Coil Style (125-150mm)
0 No Coil or Housing
1 Encapsulated
w/36" Leads
L Encapsulated w/36"
Leads & Pilot Light*
2 Encapsulated
w/DIN Connector
D Encapsulated w/DIN
Connector & Pilot Light*
3 Ind. Open Frame
w/18" Leads
* Integral pilot light. Lens color
designated separately
Standard
1 120/60
R 120/6/60
2 208/60
S 208/6/60
3 240/60
T 240/6/60
4 440/60
6 115/50
7 230/50
U 230/6/50
8 240/50
Non-Standard
A 24/60
B 288/60
C 480/60
D 24/50
E 42/50
F 48/50
G 12V DC
H 24V DC
J 230V DC
P 115/6/50
Q 440/6/60
Coil Voltage
0 No Coil
See table on page 376 for coil style/voltage
combinations.
WARNING!
ODS flanges not suitable
for use with ammonia.
!