Brochure

Table Of Contents
Catalog CIC-2003-1/US
Parker Hannifin Corporation
Climate & Industrial Controls Group
Cleveland, OH
377
Industrial Refrigeration Products: Solenoid Valves
Industrial
Refrigeration
Products
Common Specifications
Design Pressure (MRP) ............ 27.6 Bar (400 psig)
SV2 only .............................. 31.0 Bar (450 psig)
Maximum Fluid Temperature ............. 105°C (220°F)
Standard Coil Housing ................... NEMA 3R and 4
Explosion Proof Housing .......... NEMA Type 4 and 7
Solenoid Valves
The Refrigerating Specialties family of solenoid
valves includes direct operated and pilot operated
valves. Selections for most refrigeration applica-
tions are available liquid, suction, hot gas and
compressor unloading. Low or no pressure
differential, equalizing and vent solenoid in sizes
up to 50mm (2").
Explosion proof SV2X and S4X hazardous
environment type solenoids carry NEMA Type 4
and 7 classification.
Coils are stocked in standard voltages. Non-
standard voltages may be special ordered. See
table on page 394 or consult factory.
Specifications
Type S6N S8F S7 SV2 S5 S5 S4 S4 S4
Port Size
mm 5 13 20-25 13-32 32 40-75 20-32 40-100 125-200
inch
3
16" ½" ¾" - 1" ½" - 1¼"1¼"1
5
8" - 3" ¾" - 1¼"1
5
8" - 4" 5" - 8"
Seat Material PTFE PTFE PTFE PTFE PTFE Metal PTFE Metal Metal
Body Material
Ductile Ductile Gray Ductile Gray Gray Gray Gray Cast
Iron Iron Iron Iron Iron Iron Iron Iron Steel
Minimum Pressure
bar 0 0.7 0 .24 0.07 0.07 0.14 0.28 0.14
Drop to Open Wide
psi0103.511422
Minimum Fluid
°C -50° -50° -30° -45° -30° -30° -45° -50° -50°
Temperature
°F -60° -60° -25° -50° -25° -25° -50° -60° -60°
Operation
Direct Spring Electrically Spring Gravity Gravity Spring Spring Spring
Operated Closing Held Open Closing Closing Closing Closing Closing Closing
Bulletin for Reference 30-90 30-91 30-92 30-06 30-93 30-93 30-94 30-94 30-05
Selection Guide
Refrigerant VALVE MOST RECOMMENDED Listed by Port Size
Valve Refrigerant Temperature
5mm 13mm 20mm 25mm 32mm 40mm 50mm 65mm 75mm 100mm 125-200mm
Type Application Range
3
⁄⁄
⁄⁄
16" ½" ¾"1"1¼"1
5
⁄⁄
⁄⁄
8"2"2½" 3" 4" 5"- 8"
Conventional warm
S6N
S8F S4 S4 S4
S4 S4 S4 S4 S4 S4
high pressure SV2 SV2 SV2 SV2
Solenoid Liquid Above -50°C (-60° F) S6N S8F —— S4 S4 S4 S4 S4 S4
Above -45°C (-50°F) S6N
S8F S4 S4 S4
S4 S4 S4 S4 S4 S4
SV2 SV2 SV2 SV2
Suction* Above -30°C (-25°F) S6N S8F S7 S7 S5 S5 S5 S5 S5 S4 S4
Hot Gas
Below 105°C (220°F) S6N
S8F S4 S4 S4
S4 S4 S4 S4 S4 S4
Defrost SV2 SV2 SV2 SV2
Solenoid Bypass
Compressor Below 105°C (220°F) S6N S8F S7 S7 S4E S4E S4E S4E S4E S4E
Unloading
*Also see Gas Powered Suction Valves.
S4
Weld
End
S7
S6N
S8F
SV2
S5
Overview
Solenoid Valves