Brochure

Table Of Contents
Parker Hannifin Corporation
Climate & Industrial Controls Group
Cleveland, OH
Catalog CIC-2003-1/US
Distributors and Flow Controls
214
Flo-Rater Style FD20D and FD20ETechnical Information
Flo-Rater Style FD20D
Application
Designed to replace hard-to-handle and easily
damaged capillary tubing giving a more predictable
pressure drop.
Agency Approvals
UL Recognized; File No: 2709
Features and Benefits
Cost effective alternative to capillary tubes.
One piece design.
Versatility in length, end configuration, orifice size
and copper tube bend configuration.
Easy to handle and install.
Complete range of orifice sizes.
Flo-Rater Style FD20E
Application
Developed to solve space limitation
problems on Packaged Terminal
Heat Pumps and mini-split systems.
The FD20E utilizes two floating
orifices to replace two check valves
and two cap tubes along with up to
eight braze joints with one easy to
install self-contained unit requiring
only two braze joints.
Agency Approvals
UL Recognized; File No: 2709
US Patent No. 5,265,438
Features and Benefits
Cost effective alternative to capillary tubes, check
valves and strainers.
One piece design.
Bi-directional flow control/filter screen
combination.
Custom end configurations.
Complete range of orifice sizes.
Performance Specifications
Pressure up to 750 psi operating
Minimum burst pressure: 3750 psi
Operating temperature: +140°F to +250°F
(-40°C to +121°C)
Mass flow rates from 50 lb./hr. to 1200 lb./hr.
Restrictor sized from .020" to .105" (in .001"
increments)
End configurations: Male 1/4", 5/16", 3/8", 1/2"
Female 1/4", 5/16", 3/8", 1/2"
Orifice Sizing
See graphs on page 218.
Performance Specifications
Pressure up to 750 psi operating
Minimum burst pressure: 3750 psi
Mass flow rates from 50 lb./hr. to 1200 lb./hr.
Restrictor sized from .030" to .105"
(in .001" increments)
Orifice Sizing
See graphs on page 218.