T6-D-USER-AV100-EN Page 3-1 Installation
© Park Air Systems Limited 2020
3 Installation
Dangerous voltage
You must be suitably qualified to terminate a mains supply to the equipment.
Dangerous voltage
You must be careful of high RF voltages on the ANTENNA connector on the rear of the amplifier. This
is indicated by the RF voltage warning symbol ( ).
Antenna radiation
The transmit antenna must be installed such that the resultant radiated field strength is below
national limits, see Annex for limits and examples. The safe distance must be calculated for each
installation.
Earth connection
This equipment must be earthed. The earth terminal of the AC connector must be used as the safety
earth.
AC and/or DC supply
The power cables are the amplifier’s disconnect devices.
AC supply fuse rating
The amplifier AC supplies must have a 6.3 Amp time-delay fuse fitted.