User's Guide
T6T VHF 50 W Transmitter Page 29 Operation
Back to Transmitter
Main Page
BIT Status Warning Screens
The following shows some example BIT screens. These screens alternate with the Main screen when an
alert or alarm condition is present. Only the parameters causing the alert or alarm are displayed, and if
both an alert and alarm condition exists simultaneously only the alarm information is displayed. If multiple
parameters are signalling an alert or alarm condition, multiple screens are used to display the status
alternating with the Main screen.
A L E R T
S u p p l y 2 1 V
A L E R T
R F P o w e r R e d u c e d
L o o p E r r o r
S u p p l y 2 1 V
A L E R T
R F P o w e r R e d u c e d
P A T e m p 8 5 d e g C
A L A R M
R F P o w e r R e d u c e d
V S W R F A I L
A L A R M
R F P o w e r R e m o v e d
L o o p E r r o r F A I L
S u p p l y 1 8 V
A L A R M
R F P o w e r R e m o v e d
P A T e m p 9 5 d e g C
No RF power reduction
Alarm indicator flashing
RF power reduced between 1 and 3 dB
Alarm indicator flashing
RF power reduced between 1 and 3 dB
Alarm indicator flashing
RF power reduced by more than 3 dB
Alarm indicator on
RF power shut down
Alarm indicator on
RF power shut down
Alarm indicator on