User's Manual

T6T VHF 100 W Transmitter Page 4 Maintenance
Back to Transmitter
Main Page
(8) If not using 5-carrier offset, refer to AM-Voice Mode Settings Screen in the Operation section of
this document and set to the required offset.
(9) If 5-carrier offset is required, restore the carrier offset using the following routine:
Connect a 50 ohm frequency counter, through a 60 dB attenuator, to the transmitter rear
panel Antenna connector (see Fig 5 for location of the Antenna connector)
Refer to AM-Voice Mode Settings Screen in the Operation section of this document and set
the desired 5-carrier offset
Refer to Changing the Transmitter Operating Frequency in the Operation section and set the
transmitter to the nearest 25 kHz channel frequency. For example, if the required frequency
is 124.504 (+4 kHz offset), set the transmitter to 124.500 MHz
Key the transmitter and adjust the reference frequency, using the front panel Scroll/Select
switch, until the frequency counter displays the required operating frequency. For example
124.504 MHz
When the frequency counter displays the exact operating frequency, press the Scroll/Select
switch and stop keying the transmitter
Disconnect the test equipment and reconnect the antenna.