User's Manual
T6T VHF 100 W Transmitter Page 21 Operation
Back to Transmitter
Main Page
Polarities Screens AM-Voice and AM-MSK
A number of remote indication and control signals can be hardwire connected to the transmitter. These
signals include a transmitter ready indication, a PTT control signal, a phantom PTT control signal, a PTT
out indication, a transmitter inhibit control signal, an E-BIT input, a BIT test initiation control signal, an
external VSWR fault indication and antenna C/O. The following paragraphs detail the signals applicable
to the operational mode of the transmitter.
The Polarities screen is accessed from the Settings screen.
AM-Voice and AM-MSK Polarity Settings
Each of ten polarity settings applicable to AM-Voice and AM-MSK can be set to the default STD
(standard) setting or INV (inverted).
The signal connections are shown in Table 6 along with the conditions when STD or INV is selected.
The settings for the PTT Reference voltage are also shown in Table 6.
R e a d y O u t S T D
E - B I T I n S T D
I n h i b i t I n S T D
E x i t > >
B I T S t a r t I n S T D
P T T R e f + 1 4 V
P T T I n S T D
E x i t > >
P h a n P T T I n S T D
P T T O u t S T D
F a s t P T T O u t S T D
E x i t < < > >
E x t V S W R I n S T D
A n t C / O O u t S T D
B a c k