User Guide
Parasound AVC-2500 serial communication command set
30.12.1998 /Jari
Hardware specification
EIA RS-232
9600 bps, 8 bits, 1 stop bit, no parity
9-pin female (DCE) D-connector, TXD on pin 2, RXD on pin 3, GND on pin 5
ASCII transmission, no flow control
Software specification
Serial communication command format
<zone><field separator><command><field separator><parameter 1><field separator><parameter 2><line terminator>
field purpose possible values
<zone> target zone for the command numbers from 1 to 2
<command> a command identification numbers from 1 to N
<parameter 1> an optional parameter for the command none, or numbers from -N to N, depending on command
<parameter 2> another optional parameter for the command none, or numbers from -N to N, depending on command
<field separator> separator for fields in the command line one or more spaces
<line terminator> terminator for the command line either CR or LF
Notes
blank lines or lines starting with '#' character are ignored
a CR/LF (or LF/CR) character pair is a valid line terminator
response to illegal command input is undefined, usually the command is just ignored
parameters which aren't required by the command are ignored
Serial communication zones
zone target zone
1 Zone 1, aka Main
2 Zone 2, aka Zone
Sample Rate Systems Oy Page 1