6.
Securely snap all six oval slot plugs provided
into the six slots in the drain cover support
plate. Use the plugs without tabs (marked C)
over screws (tabs may be broken off if
necessary). When tabs are broken off the tree
the attachment points at each end must be
trimmed flush for the part to fit snugly in the
support plate. CAUTION: FAILURE TO
PROPERLY INSTALL THE PLUGS COULD
DISABLE THE SAFETY FEATURES OF THE
SDX RETRO
(Fig. 10)
.
7.
Attach the drain cover to the drain cover
support plate using the tool and the three
10x7/8 security screws provided
(Fig. 11)
.
Paramount requires the use of security screws
to secure the cover. Completely hand tighten
screws. Do not use power tools.
8.
If the SDX Retro is on a curved wall such as a
spa, or the wall/floor of the pool is un-even,
then the gap between the back plate of the
SDX and the pool finish must be filled. An
under water epoxy such as AB epoxy putty
may be used or if the pool is empty then silicon
glue may be used. Allow for drying time in both
cases before suction is applied to the drain
cover.
Fig. 8: Attached without Spacers and
Threaded Inserts
Fig. 9: Attached with Both Spacers
and Threaded Inserts
Fig. 10: Install Slot Plugs
Trim tabs
flush to fit in
support plate