8.0 ELECTRICAL CHARACTERISTICS
8.1. Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress
ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the
remainder of Section 7.0. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability.
Table 18: Absolute Maximum Ratings
Ambient temperature under bias
-55 °C to +125 °C
Storage temperature
-65 °C to +150 °C
Voltage on V
dd
with respect to V
ss
-0.3 V to +4.0 V
Voltage on all other pins with respect to V
ss
-0.3 V to (V
dd
+ 0.3 V)
Total power dissipation 1 W
Max. current out of V
ss
pins
300 mA
Max. current into V
dd
pins
300 mA
Max. DC current into an input pin with internal protection diode forward biased ±500 µA
Max. allowable current per I/O pin
40 mA
ESD (Human Body Model) Supply pins 3 kV
ESD (Human Body Model) all non-supply pins 8 kV
8.2. DC Characteristics
(Operating temperature range: -55° C < T
a
< +125° C unless otherwise noted)
Symbol Parameter Conditions Min Typ Max Units
V
dd
Supply Voltage 2.7
-
3.6 V
V
ih,
V
il
Logic High
Logic Low
0.6 V
dd
V
ss
V
dd
0.3 V
dd
V
V
I
il
Input Leakage Current
V
in
= V
dd
or V
ss
-1.0 +1.0 µA
V
oh
Output High Voltage
I
oh
= 10 mA, V
dd
= 3.3 V
2.85
V
V
ol
Output Low Voltage
I
ol
= 10 mA, V
dd
= 3.3 V
0.4 V
I
BO
Brownout Detector Current 3.8 µA
I Quiescent Current RESn = 0V, BOEn = V
dd
, P
0
-P
31
=0V 600 nA
Note: Data in the Typical (“Typ”) column is T
a
= 25 °C unless otherwise stated.
8.3. AC Characteristics
(Operating temperature range: -55°C < T
a
< +125°C unless otherwise noted)
Symbol Parameter Min Typ Max Units Condition
F
osc
External XI Frequency
DC
-
80 MHz
Oscillator Frequency DC
13
8
4
-
20
12
-
80
33
20
8
MHz
kHz
MHz
MHz
Direct drive (no PLL)
RCSLOW
RCFAST
Crystal using PLL
C
in
Input Capacitance
6
-