Modem User's Guide
Table Of Contents
- Contents
- Warranty, Sales, and Service Information
- About This Guide
- About the Model 7986 Standalone Termination Unit
- Using the Asynchronous Terminal Interface
- Initial Startup and Configuration
- Monitoring the Unit
- Testing
- Messages and Troubleshooting
- Security
- IP Addressing
- Configuration Option Tables
- Standards Compliance for SNMP Traps
- Cables and Pin Assignments
- Technical Specifications
- Glossary
- Index

Configuration Option Tables
A-9
7986-A2-GB20-00
September 1998
Table A-4. Communication Port Options (2 of 3)
Data Rate
Possible Settings: 9.6, 14.4, 19.2, 28.8, 38.4
Default Setting: 9.6
Specifies the communication port baud rate.
9.6 – Communication port rate is 9600 bps (Terminal).
14.4 – Communication port rate is 14400 bps (Netlink).
19.2 – Communication port rate is 19200 bps (Netlink).
28.8 – Communication port rate is 28800 bps (Netlink).
38.4 – Communication port rate is 38400 bps (Netlink).
Character Length (Asynchronous mode only)
Possible Settings: 7, 8
Default Setting: 8
Determines the character length of the communication port.
7 – The character length of the communication port is seven bits.
8 – The character length of the communication port is eight bits.
Parity (Asynchronous mode only)
Possible Settings: None, Odd, Even
Default Setting: None
Specifies the parity of the communication port.
None – No parity used.
Odd – Odd parity used.
Even – Even parity used.
Stop Bits (Asynchronous mode only)
Possible Settings: 1, 1.5, 2
Default Setting: 1
Specifies the number of stop bits for the communication port.
1 – One stop bit.
1.5 – One and one half stop bits.
2 – Two stop bits used.
Ignore Control Leads (Asynchronous mode only)
Possible Settings: Disable, DTR
Default Setting: Disable
Specifies whether DTR is used.
Disable – Control leads are treated as standard.
DTR – DTR is ignored.