User's Manual

required data is entered, the keypad will emit a
confirmation beep and the Parakey will
automatically save and exit the section. If you make
a mistake, pressing [CLEAR] when entering data will
erase the current entry. Return to step 3 or press
[CLEAR] to exit Programming Mode.
Sections [09] to [16]
RF Programming - Press the [ENTER] key and press
button 1 twice on the remote control to assign
remote control to corresponding user. The keypad
will emit a confirmation beep and the Parakey will
save and exit the section. Return to step 3 or press
[CLEAR] to exit Programming Mode.
Sections [25] - [30]
Decimal Select - Each section represents one
feature and each key from [0] to [8] represents a
specific setting. Unlike feature select programming,
only one key can be selected. The selected key will
remain illuminated. Press the key representing the
desired setting and press [ENTER].
Sections [17] - [24] & [31] - [35]
Feature Select - After entering the section, each key
from [1] to [8] represents a feature or option. The on/off
status of these keys determines the feature's setting.
Turn the keys on/off by pressing the appropriate key
until the desired options are set and press the [
ENTER]
key. The keypad will emit a confirmation beep and the
Parakey will save and exit the section. Return to step
3 or press [CLEAR] to exit Programming Mode.
PROGRAMMING THE SYSTEM
Section [35] - Feature Select Programming: [1]
The Parakey can be set to accept 6-digit or 4-digit User
and Installer Access Codes.
Key [1] OFF = 4-digit access codes.
Key [1] ON = 6-digit access codes (default).
This option must be set to the same access code
length as set in the control panel at address 088,
key [9].
Section [00] - Access Code Programming
The Installer Code provides you with access to program
all the functions & features of the Parakey System. The
Installer Code can be 4 or 6 digits in length (see section
4.1) with each digit being any value from 0 to 9.
The Parakey system supports up to eight users, each with a
different remote control. As demonstrated in figure 5, the
three parameters listed below are specific to each user and
each user must be defined with all three of these parameters.
User Access Code
Remote Control Assignment
User Remote Control Options
4.3 User Parameters
4.2 Installer Code (Default: 757575)
4.1 Access Code Length
12 13