Panic Output Programming
Section [25]: __
(select one digit only)
ÔÔ
[0] = Disabled
[1] = Activate output 1 on panic alarm
[2] = Activate output 2 on panic alarm
* [3] = Activate output 3 on panic alarm
[4] = Activate output 4 on panic alarm
Panic Lockout Timer
Section [26]: __
(select one digit only)
ÔÔ
* [0] = Disabled
[1] = 30 second signal lockout on panic alarm
[2] = 60 second signal lockout on panic alarm
[3] = 90 second signal lockout on panic alarm
[4] = 120 second signal lockout on panic alarm
Key Key Key Description
[1]
[2
]
[3
]
____________________________________________
Off Off Off No Arming & Disarming
On Off Off * Button 1 = Regular Arming
Off On Off Button 2 = Regular Arming
On On Off Button 1 = Regular Arming
Button 2 = Regular Arming
Off Off On Button 1 = Away Arming
On Off On Button 1 = Away Arming
Button 2 = Stay Arming
Off On On Button 1 = Regular Arming
Button 2 = Stay Arming
On On On Button 1 = Stay Arming
Section [35]: General Options
OFF Key ON
4-Digit __ [1] __ * 6-Digit Access Codes
PGM only __ [2] __ *
Panic activates enabled PGM & sends
panic command to control panel
PGM Options Keys (on/off)
[1] [2] [3] [4]
PGM1 PGM2 PGM3 PGM4
Section [31]: Button 1 (default: [1] on) ___ ___ ___ ___
Section [32]: Button 2 (default: [2] on) ___ ___ ___ ___
Section [33]: Button 3 (default: [3] on) ___ ___ ___ ___
Section [34]: Button 4 (default: [4] on) ___ ___ ___ ___
Key ON activates corresponding PGM
Key OFF disables corresponding PGM
PGM Options Timing
Section [27]: __ PGM 1
(select one digit only)
Section [28]: __ PGM 2
(select one digit only)
Section [29]: __ PGM 3
(select one digit only)
Section [30]: __ PGM 4
(select one digit only)
ÔÔ
[0] = Latched [3] = 10 seconds [6] = 60 seconds
[1] = 1 second [4] = 20 seconds [7] = 2 minutes
*
[2] = 5 seconds [5] = 40 seconds [8] = 4 minutes