User's Manual
Table Of Contents
- Introduction
- About Magellan and this Manual
- Conventions
- Specifications
- Quick Setup
- Installation
- AC Power
- DC Power
- Backup Battery Pack
- Auxiliary Output
- Telephone Line Connections
- Programmable Outputs (PGMs)
- Hardwire Zone Connections
- WinLoad Connection
- UIP-256 Universal In-Field Programmer Connection
- X10 Transmitter Connection (MG-6160 only)
- Connecting a Paradox Memory Key (PMC-3)
- Location and Mounting
- Connecting the Radio Antenna (MG-6160 only)
- Programming Methods
- WinLoad Installer Upload/Download Software
- Programming Using the Built-in Keypad
- Programming Using a Paradox Memory Key
- User Codes
- User Code Length
- Installer Code
- Maintenance Code
- System Master Code
- Duress Code
- Zone Programming
- Zone Programming Overview
- Zone Definitions
- Zone Options
- Zones 31 and 32 Become Hardwire Zones
- EOL (End-Of-Line) Zones
- Assigning Wireless Zone Transmitters
- Assigning Wireless Doorbells to the Console
- Deleting Assigned Wireless Transmitters
- Viewing Wireless Transmitter Signal Strength
- Assigning Remote Controls
- Programming the Remote Control’s Buttons
- Assigning Wireless Keypads
- Assigning Wireless Repeaters
- Wireless Repeater Options
- Arming and Disarming
- Regular Arming Switches to Stay Arming
- Regular Arming Switches to Force Arming
- Stay Arming Switches to Force Arming
- Timed Auto-Arming
- No Movement Auto-Arming
- Auto-Arming Options
- One-Touch Arming
- Exit Delay
- Bell Squawk on Arm/Disarm with Remote Control
- No Exit Delay when Arming with Remote Control
- Exit Delay Termination
- Follow Zone Switches to Entry Delay 2
- Closing Delinquency Timer
- Stay Arm Siren Delay
- Alarm Options
- Bell Cut-off Timer
- Wireless Transmitter Supervision Options
- Check-in Supervision Options
- Tamper Recognition Options
- Wireless PGM Supervision Options
- Wireless Keypad Supervision Options
- Wireless Repeater Supervision Options
- Wireless PGM Console Supervision Options (Follow Alarm/Follow Bell)
- Backup Alarm Reporting Option
- Panic Alarms
- Reporting and Dialer Settings
- Report Codes
- Console Telephone Numbers
- Console Account Number
- Reporting Formats
- Event Call Direction
- Delay Between Dialing Attempts
- Alternate Dial Option
- Force Dial Option
- Dialing Method
- Pulse Ratio
- Switch to Pulse Dialing on 5th Attempt
- Telephone Line Monitoring (TLM)
- Recent Close Delay
- Auto-Test Report
- Power Failure Report Delay
- Disarm Reporting Options
- Zone Restore Report Options
- RF Jamming Supervision
- Programmable Outputs
- Assigning PGMs
- Setting PGM Function
- Onboard PGM Activation Event
- Onboard PGM Deactivation Event
- Onboard PGM Delay
- PGM Normal State (Onboard Only)
- PGM X10 Option (MG-6160 Only / Onboard Only)
- Wireless PGM Activation Event
- Wireless PGM Deactivation Event
- Wireless PGM Delay
- System Settings
- Software Reset
- Installer Lock
- Console Tamper Supervision
- Console Audible Trouble Warning
- FM Tuner Option (MG-6160 only)
- Daylight Savings Time
- AC Power Failure Warning
- The Trouble Display
- WinLoad Software Settings
- Panel Answer Options
- Panel Identifier
- PC Password
- PC Telephone Number
- Call Back Feature
- Appendix 1: Automatic Report Code List
- Appendix 2: Ademco Contact ID Report Code List
- Index
34 Reference & Installation Manual
Programmable Outputs
A PGM is a programmable output that toggles to its opposite
state (i.e. a normally open PGM will close) when a specific event
has occurred in the system. For example, a PGM can be used to
activate bells or strobe lights, open/close garage doors and
much more. When a PGM activates, the control panel triggers
any device or relay connected to it. The Magellan console
includes two onboard PGMs. It can support up to a total of four
PGMs (e.g., two onboard PGMs + two wireless PGMs OR four
wireless PGMs).
Assigning PGMs
Sections [235] to [238]: PGMs 1 to 4
Sections [235] to [238] represent PGMs 1 to 4. A PGM module
assigned to a section ([235] to [238]) will be assigned to the PGM
represented by the section.
For example, a PGM module assigned to section [235] will be
assigned to PGM1.
To assign a PGM:
1. Access the installer programming mode (see page 13).
2. Enter the [
SECTION] corresponding to the desired zone.
3. Enter the 6-digit [SERIAL NUMBER] of the PGM module.
The serial number is located on the inside of the PGM module.
The PGM module must be activated once having been assigned
to the Magellan console. To activate a PGM module, insert the
batteries and close the cover.
PGM 1 and 2 are onboard. PGM 3 and 4 are wireless.
Setting PGM Function
This feature allows you to program the Magellan console to
recognize PGM1 and/or PGM2 as a hardwire PGM (onboard)
and PGM 3 and/or 4 as wireless. To set a PGM’s function:
1. Press [
MENU] + [4] + [INSTALLER CODE] + [7].
2. Press [
OK] to set the function of PGM1 or [NEXT] to set the
function of PGM 2, 3, and/or 4. Press [
OK] to set the function
of the desired PGM module.
3. Press [
YES] to set the PGM as wireless.
4. Open and then close the cover of the wireless PGM module.
The PGM function has been set.
5. To continue programming the module, follow the instructions
on the Magellan console.
To program the PGM’s activation event and/or deactivation
event, see Onboard PGM Activation Event on page 34, Wireless
PGM Activation Event on page 35, Onboard PGM Deactivation
Event on page 34 and Wireless PGM Deactivation Event on
page 35.
If both PGM1 and PGM2 are set as hardwire (onboard),
Magellan will ignore sections [260] to [267], and [280] to [283].
Onboard PGM Activation Event
Section [086] = PGM1 Activation Event
Section [088] = PGM2 Activation Event
This feature allows you to program the Magellan console to
activate a PGM when a specific event occurs in the system. The
PGM will remain in its active state until the programmed PGM
Deactivation Event (see page 34) occurs or when the PGM
Delay (see page 34) elapses. To program a PGM Activation
Event:
1. Enter the section that corresponds to the desired PGM;
PGM1 = [086], PGM2 = [088].
2. Enter the [
EVENT GROUP #].
3. Enter the [SUB-GROUP #].
The AC Loss PGM event (Event Group #28, Event Sub-group
#01) will only occur after the Power Failure Report Delay
elapses (see page 33).
For the Event List, see the PGM Table in the Magellan
Programming Guide.
Onboard PGM Deactivation Event
Section [087] = PGM1
Section [089] = PGM2
After PGM activation (see Onboard PGM Activation Event on
page 34), the PGM will return to its normal state (deactivate)
when the programmed PGM Deactivation Event occurs. To
program a Deactivation Event:
1. Enter section that represents the desired PGM; PGM1 =
[087], PGM2 = [089].
2. Enter the [
EVENT GROUP #].
3. Enter the [SUB-GROUP #].
A PGM can also be set to deactivate after a programmed period
elapses (see Onboard PGM Delay on page 34). If using the
PGM Delay, sections [087] and [089] can be used as an
additional PGM Activation Event.
For the complete Event List, see the PGM Table in the
Magellan Programming Guide.
Onboard PGM Delay
Section [068] = PGM1, Section [069] = PGM2
001 to 255 seconds; 000 = Follow Deactivation Event;
Default = 5 seconds
Instead of deactivating the PGM on the occurrence of a specific
event, the PGM will deactivate after the period programmed in
here has elapsed. Enter 000 to have the PGMs deactivate with a
PGM Deactivation Event (see page 34).
If a PGM Delay is programmed, the corresponding PGM
Deactivation Event can be used as an additional PGM Activation
Event.