User's Manual
Table Of Contents
- Introduction
- About Magellan and this Manual
- Conventions
- Specifications
- Quick Setup
- Installation
- AC Power
- DC Power
- Backup Battery Pack
- Auxiliary Output
- Telephone Line Connections
- Programmable Outputs (PGMs)
- Hardwire Zone Connections
- WinLoad Connection
- UIP-256 Universal In-Field Programmer Connection
- X10 Transmitter Connection (MG-6160 only)
- Connecting a Paradox Memory Key (PMC-3)
- Location and Mounting
- Connecting the Radio Antenna (MG-6160 only)
- Programming Methods
- WinLoad Installer Upload/Download Software
- Programming Using the Built-in Keypad
- Programming Using a Paradox Memory Key
- User Codes
- User Code Length
- Installer Code
- Maintenance Code
- System Master Code
- Duress Code
- Zone Programming
- Zone Programming Overview
- Zone Definitions
- Zone Options
- Zones 31 and 32 Become Hardwire Zones
- EOL (End-Of-Line) Zones
- Assigning Wireless Zone Transmitters
- Assigning Wireless Doorbells to the Console
- Deleting Assigned Wireless Transmitters
- Viewing Wireless Transmitter Signal Strength
- Assigning Remote Controls
- Programming the Remote Control’s Buttons
- Assigning Wireless Keypads
- Assigning Wireless Repeaters
- Wireless Repeater Options
- Arming and Disarming
- Regular Arming Switches to Stay Arming
- Regular Arming Switches to Force Arming
- Stay Arming Switches to Force Arming
- Timed Auto-Arming
- No Movement Auto-Arming
- Auto-Arming Options
- One-Touch Arming
- Exit Delay
- Bell Squawk on Arm/Disarm with Remote Control
- No Exit Delay when Arming with Remote Control
- Exit Delay Termination
- Follow Zone Switches to Entry Delay 2
- Closing Delinquency Timer
- Stay Arm Siren Delay
- Alarm Options
- Bell Cut-off Timer
- Wireless Transmitter Supervision Options
- Check-in Supervision Options
- Tamper Recognition Options
- Wireless PGM Supervision Options
- Wireless Keypad Supervision Options
- Wireless Repeater Supervision Options
- Wireless PGM Console Supervision Options (Follow Alarm/Follow Bell)
- Backup Alarm Reporting Option
- Panic Alarms
- Reporting and Dialer Settings
- Report Codes
- Console Telephone Numbers
- Console Account Number
- Reporting Formats
- Event Call Direction
- Delay Between Dialing Attempts
- Alternate Dial Option
- Force Dial Option
- Dialing Method
- Pulse Ratio
- Switch to Pulse Dialing on 5th Attempt
- Telephone Line Monitoring (TLM)
- Recent Close Delay
- Auto-Test Report
- Power Failure Report Delay
- Disarm Reporting Options
- Zone Restore Report Options
- RF Jamming Supervision
- Programmable Outputs
- Assigning PGMs
- Setting PGM Function
- Onboard PGM Activation Event
- Onboard PGM Deactivation Event
- Onboard PGM Delay
- PGM Normal State (Onboard Only)
- PGM X10 Option (MG-6160 Only / Onboard Only)
- Wireless PGM Activation Event
- Wireless PGM Deactivation Event
- Wireless PGM Delay
- System Settings
- Software Reset
- Installer Lock
- Console Tamper Supervision
- Console Audible Trouble Warning
- FM Tuner Option (MG-6160 only)
- Daylight Savings Time
- AC Power Failure Warning
- The Trouble Display
- WinLoad Software Settings
- Panel Answer Options
- Panel Identifier
- PC Password
- PC Telephone Number
- Call Back Feature
- Appendix 1: Automatic Report Code List
- Appendix 2: Ademco Contact ID Report Code List
- Index
Paradox Magellan Systems 23
Auto-Arming Options
Section [092]: Option [3]
Option [3] OFF = Auto-arm system using Regular arm (default)
Option [3] ON = Auto-arm system using Stay arm
When using Timed Auto-arming (see page 22) or No Movement
Auto-Arming (see page 22), the console can Regular or Stay arm
the system.
This feature is not for use in UL installations.
One-Touch Arming
Section [092]: Options [7] and [8]
Option [7] OFF = One-touch Regular/Force arming disabled
Option [7] ON = One-touch Regular/Force arming enabled
(default)
Option [8] OFF = One-touch Stay arming disabled
Option [8] ON = One-touch Stay arming enabled (default)
The One-touch arming features allow users to arm the system
without having to enter any Access codes. To arm the system,
press and hold the appropriate key for approximately 2 seconds.
Exit Delay
Section [062]: 001 to 255 seconds; 000 = disabled; Default = 60
seconds
The Exit Delay determines the amount of time a user has to
leave the protected area before Magellan arms the system. The
Exit Delay applies to all zones (except 24Hr zones) in the
system. Program the Exit Delay from 001 to 255 seconds.
Bell Squawk on Arm/Disarm with Remote
Control
Section [093]: Option [3]
Option [3] OFF = Bell squawk disabled (default)
Option [3] ON = Bell squawk enabled
When option [3] is enabled (ON), the siren will squawk once
upon arming with a remote control and twice upon disarming with
a remote control.
This feature must be enabled in UL installations.
No Exit Delay when Arming with Remote
Control
Section [093]: Option [4]
Option [4] OFF = Provides Exit Delay when arming with remote
control (default)
Option [4] ON = No Exit Delay when arming with remote control
When option [4] is enabled (ON), the console cancels the Exit
Delay (arms instantly) when the system is armed with a remote
control. When disabled, the Exit Delay Timer will start when the
system is armed with a remote control.
Exit Delay Termination
Section [093]: Option [6]
Option [6] OFF = Exit Delay Termination disabled
Option [6] ON = Exit Delay Termination enabled (default)
When option [6] is enabled (ON), the console will reduce the Exit
Delay to 10 seconds when an Entry Delay zone (see Exit Delay
on page 23) is opened and closed during the Exit Delay.
Example: 15 seconds into a 45 second Exit Delay, an Entry
Delay zone opens and closes. The remaining 30 seconds is
reduced to 10 seconds.
Follow Zone Switches to Entry Delay 2
Section [093]: Option [7]
Option [7] OFF = Follow zone triggers an alarm (default)
Option [7] ON = Follow zone follows Entry Delay 2 when
opened
When option [7] is enabled (ON) and an Entry Delay 1 zone is
bypassed, an armed Follow zone that opens without an Entry
Delay being triggered will switch to the Entry Delay 2 timer.
Example: Zone 1 is an Entry Delay zone and zone 2 is a Follow
zone protecting the area where the keypad is installed. The
system is armed but zone 1 is bypassed. With option [7] enabled,
zone 2 will switch to and wait for the Entry Delay 2 timer to
elapse before triggering an alarm.
Closing Delinquency Timer
Section [080]: 001 to 255 days; 000 = Disabled; Default = 000
The Magellan console will verify when the system was last
armed at midnight of every day. If the last time the system was
armed is greater than the programmed Closing Delinquency
timer, the console will transmit a Closing Delinquency report
code (see page 28) to the monitoring station.
Enter a value from 001 to 255 days into section [080] to program
the Closing Delinquency timer. Enter 000 to disable the timer.
Stay Arm Siren Delay
Section [095]: Option [4]
Option [4] OFF = Stay Arm Siren Delay disabled
Option [4] ON = Stay Arm Siren Delay enabled (default)
When option [4] is enabled and an alarm is triggered on a stay
armed system, the console plays an audible 15-second
countdown that will increase in volume as the countdown
progresses. While the system reports the alarm to the monitoring
station immediately upon being triggered, the siren will not
activate until the 15-second siren delay is complete.