2.6 MG5050 / MG5050 EN PCB Layout
Used for In-Field Firmware
upgrade through a 307USB
Direct Connect Interface.
See Connecting to WinLoad
on page 51 for details.
Antenna
Do not cut, bend or alter
the antennas and ensure
that electrical wires do not
cross over the antennae,
as this may affect signal
reception.
Four pin connector can
be used for quick
installation of a
MG5050 keypad.
Refer to AC Power
& Backup Battery
Connections on
page 3.
Charge LED:
Charging and battery
test LED
Status LED:
• Flash once every
second = Normal
•Flashes ON 1
second and OFF 1
second = Any
trouble
• Always ON = Panel
is using phone line
• Fast flash 6
seconds after power
up = Installer lock
enabled
"RX" & “TX” LED:
Flashes quickly when
receiving or
transmitting RF signals
from wireless devices.
To metallic
enclosure
Ground
clamp
AWG#14 single conductor
solid copper wire
Cold water
pipe grounding
The "BELL" output will
shutdown if the current
exceeds 3A.
Refer to
Single
Zone
Inputs
on
page 6
Max. amount of keypads = 15 keypads
Max. current = 700 mA
Max. distance of keypad from panel = 76m (250 feet)
Max. total run of wire = 230m (750 feet)
BUS (RED BLK GRN YEL)
Connect Paradox devices accordingly.
This is a unique connection interface
used for interconnection between
Paradox devices.
This equipment must be installed and maintained by qualified service personnel only.
For UL and C-UL warnings, refer to the UL and C-UL Warnings section at the back of the Reference & Installation Manual.
Press and hold the RESET button for
five seconds. The STATUS LED will
start flashing. Within 2 seconds of this
flashing, press the reset switch again.
The panel will reset to default and
restart.
EBUS and Dialer used for
VDMP3 plug-in voice module
for voice reporting.
PGM Trigger: This
jumper allows you to
choose whether the solid
state relay PGM (PGM4
only) is grounded (-), or
gives out 12V (+).
For the keypad’s zone
configurations, refer to the
Installer Quick Menu. If EOL
is enabled: see section [706]
option [2]. Also refer to Single
Zone Inputs on page 6.
Disconnect
telephone
line before
servicing.
MG5050 EN 50131 Immunity to Attenuation Test
When performing the attenuation test, replace antenna A with the following:
• For a 433 MHz panel, use an antenna with a length of 10.2 cm (4 in.)
• For a 868 MHz panel, use an antenna with a length of 6.1 cm (2.4 in.)
Once the test is complete, reinsert the original antenna (A) in its place, and
connect the wires (not shown) to a zone input programmed for tamper.
Tamper
antenna for
EN 50131
compliancy
To provide maximum
lightning protection we
strongly recommend having
separate earth connections
for the dialer and zone
ground terminals.