User's Manual
Table Of Contents
- Basic Operations
- Programming Access Codes
- System Master Code (Default: 123456)
- Master Codes
- Duress Code
- Programming Access Codes
- 2. Enter your [system master code] or either [master code].
- 3. The [] key will flash. When a zone LED or zone key is lit (not flashing), the user is already programmed.
- 4. Select a user by entering a 2-digit user number (i.e. [0]+[9] for user 9) or use the scroll keys and then press [enter]. For the MG10LEDV/H, press the key corresponding to the user number (i.e. [9] for user 9).
- 5. Enter a new 4- or 6-digit [access code].
- 6. Confirm the code.
- 7. Press a button on the designated remote or press [enter] to skip if there is no remote to program.
- 8. (Not available for non-partitioned system) Press [1] and/or [2] to assign the user to a partition. Press [enter], the menu will now jump to the next available user, if you choose to continue.
- 2. Enter your [system master code] or either [master code].
- 3. Select a user by entering a 2-digit user number (i.e. [0]+[9] for user 9). For the MG10LEDV/H, enter a 1-digit user number (i.e. [9] for user 9).
- 4. Press the [sleep] key until you hear the confirmation beep.
- Regular Arming
- Sleep Arming
- Stay Arming
- One-Touch Arming
- Auto-Arming
- Timed Auto Arming
- 2. Enter [master code].
- 3. Press the [byp] key. The [byp] key will flash to indicate you are in the System Options menu.
- 4. Press key [1] to set partition 1, or press key [2] to set partition 2.
- 5. Enter the desired time for auto arm (24 hour clock, e.g. 18:30).
- 6. Press key [1] to regular arm, key [2] to sleep arm, or key [3] to stay arm the partition.
- No Movement Auto Arming
- Timed Auto Arming
- Disarming & Deactivating an Alarm
- 2. Press [off] + enter [access code].
- 3. If you have access to both partitions (see Partitioning on page 3): Press the key corresponding to the desired partition ([1] or [2]). For both partitions, press the other key after the confirmation beep.
- Manual Bypass Programming
- 2. Enter your [access code] (see the note below). The [byp] key will flash.
- 3. Illuminate the number(s) corresponding to the zone(s) you want to bypass by entering the two-digit zone number (i.e. zone 3 = 03). Solid on = Zone open, Flash = Zone bypass, Off = Zone closed, not bypassed.
- 4. Press the [enter] key to save and exit.
- Bypass Recall Feature
- Display Mode
- Alarm Display
- Fire Alarms
- Panic Alarms
- Programming Chime Zones
- Keypad Muting
- Keypad Backlight
- PGM Keys (Programmable Outputs)
- Power Save Mode
- Trouble Display
- 2. Read the corresponding explanation of the trouble from the Trouble List below. If no repair instructions are given, call your monitoring station for repairs.
- 3. Press the [clear] key to exit.
- Trouble List
- 2. Enter the hour and minutes. If the hour is between 01 and 12, you will need to select [1] for 24Hr format, [2] for AM, and [3] for PM setting. If the hour is above 12, the system will automatically select the 24Hr format.
- 3. Enter the year (4 digits).
- 4. Enter the month (2 digits).
- 5. Enter the day (2 digits). You have now set the Time & Date. Press [clear] to exit.
- Quick Function Keys
- Testing & Maintenance
- System Checklist
- Master Quick Menu MG5000
- Overview
- User
- PGMs
- PGM Utility Keys
- System Timers
- Other Information
- Access Codes
- 2. The [] key will flash. When a zone LED or zone key is lit (not flashing), the user is already programmed.
- 3. Select a user by entering a 2-digit user number (i.e. [0]+[9] for user 9) or use the scroll keys and then press [enter]. For the MG10LEDV/H, press the key corresponding to the user number (i.e. [9] for user 9).
- 4. Enter a new 4- or 6-digit [access code].
- 5. Confirm the code.
- 6. Press a button on the designated remote or press [enter] to skip if there is no remote to program.
- 7. (Partitioned system only) Press [1] and/or [2] to assign the user to a partition. Press [enter], the menu will now jump to the next available user.
Magellan 7
Auto-Arming
The Magellan alarm system can be programmed to automatically arm upon the following two conditions.
Timed Auto Arming
The alarm system can automatically arm itself at a specified time everyday. As with Regular arming (see page 5), the system will
bypass any open zones. Your installer can enable this option, but you can program the time of day the system will automatically arm.
No Movement Auto Arming
The alarm system can be programmed to arm the system and/or send a report if no zone activity occurs for a pre-programmed
amount of time. This is a particularly useful feature when supervising an individual with chronic health problems or a person who
lives alone. The system will bypass any open zones. This feature must be set by your installer.
Disarming & Deactivating an Alarm
To disarm an armed system or an alarm, press [OFF] and enter your [ACCESS CODE]. An entry point, like the front door, will be
programmed with one of two Entry Delay Timers. When an entry point is opened, the keypad will beep until you disarm the system.
Your alarm system will not generate an alarm until this timer elapses. Any user can disarm a partition they have been assigned to,
except users assigned with the Arm Only Option or PGM Only Option.To disarm alarms generated by a Delayed Fire Zone, please
refer to Fire Alarms on page 9.
Manual Bypass Programming
Manual Bypass Programming allows you to program the alarm system to ignore (deactivate) specified zones the next time the
system is armed. For example, you may wish to bypass certain zones when workers are renovating part of your establishment. Once
the system is disarmed, the bypass entries are erased. Manual Bypass Programming can also be activated by using One-Touch
Bypass Programming (see note below). To remove the Bypass feature from a zone, in step 3 enter the zone number again or press
[
CLEAR] to erase all current entries. When zones are bypassed, the [BYP] key will illuminate.
If One-Touch Bypass Programming is enabled, press the [BYP] key for three seconds to enter Bypass Programming.
Press [
ENTER] after step 2 to bypass all open zones. Press [CLEAR] twice to exit without saving. Press [CLEAR] + [ENTER] to delete bypassed
zones.
How do I program the Auto-Arm Timer?
1. Press the [] key.
2. Enter [MASTER CODE].
3. Press the [BYP] key. The [BYP] key will flash to indicate you are in the System Options menu.
4. Press key [1] to set partition 1, or press key [2] to set partition 2.
5. Enter the desired time for auto arm (24 hour clock, e.g. 18:30).
6. Press key [1] to regular arm, key [2] to sleep arm, or key [3] to stay arm the partition.
How do I disarm the system?
For a Stay or Sleep armed system, go to step 2.
1. Enter through a designated entry point (i.e. front door).
2. Press [
OFF] + enter [ACCESS CODE].
3. If you have access to both partitions (see Partitioning on page 3): Press the key corresponding to the desired partition ([1] or [2]).
For both partitions, press the other key after the confirmation beep.
How do I deactivate an alarm?
Press [
OFF] + enter [ACCESS CODE].
How do I bypass zones?
1. Press the [
BYP] key.
2. Enter your [
ACCESS CODE] (see the note below). The [BYP] key will flash.
3. Illuminate the number(s) corresponding to the zone(s) you want to bypass by entering the two-digit zone number (i.e. zone 3 =
03). Solid on = Zone open, Flash = Zone bypass, Off = Zone closed, not bypassed.
4. Press the [
ENTER] key to save and exit.