7.14 No Exit Delay Beeps and No Bell Squawk When Stay Arming
Section [131]: Arming/Disarming Options
Option [5] OFF = No Exit Delay Beeps and No Bell Squawk When Stay Arming Disabled (default)
Option [5] ON = No Exit Delay Beeps and No Bell Squawk When Stay Arming Enabled
With this feature enabled, the control panel will prevent the bell or siren from squawking and the keypads from beeping during the
exit delay, whenever a partition is Stay armed.
Part 8: Alarm Options
8.1 Bell Cut-Off Timer
Section [073] = Partition 1, [074] = Partition 2
000 = Disabled, 001 to 255 minutes, Default = 4 minutes, 5 minutes minimum for ULC installations
After an audible alarm, the bell or siren will stop upon disarming of the partition or when the Bell Cut-Off Timer has elapsed,
whichever comes first.
8.2 Recycle Alarm
After the Bell Cut-Off Timer and the Recycle Delay have elapsed, the control panel will re-verify the zone status. If there are any
open zones, the control panel will generate another alarm. In one armed period, the control panel will repeat this sequence the
number of times defined by the Recycle Counter.
8.2.1 Recycle Alarm Delay
Section [090]
000 = disabled, 001 to 255 minutes, Default = Disabled
The Recycle Delay determines the amount of time after Bell Cut-Off that the control panel will wait before re-verifying
zone status.
8.2.2 Recycle Counter
Section [091]
000 = disabled, 001 to 255, Default = Disabled
The Recycle Counter determines the number of times the control panel will re-verify the zone status after Bell Cut-Off
in one armed period.
8.3 Tamper Recognition
Section [132]: Zone Options
[1] OFF / [2] OFF: Tamper Recognition Disabled (default)
If the system is armed or disarmed
, the control panel will display the zone as open in the keypad display, but will not generate
an alarm. This option is not permitted on UL systems.
[1] OFF / [2] ON: Trouble Only
If the system is armed
and a tamper wiring failure occurs on a zone, the control panel will follow the zone's Alarm Types setting
(see page 16).
If the system is disarmed
and a tamper wiring failure occurs on a zone, a Tamper/Zone Wiring Failure will appear
in the keypad’s trouble display (see page 42) and the control panel will transmit the appropriate Zone Tamper report code (see
page 29).
[1] ON / [2] OFF: Silent Alarm
If the system is armed
and a tamper wiring failure occurs on a zone, the control panel will follow the zone's Alarm Types setting
(see page 16). In a disarmed system, it functions the same as the Trouble Only setting, but it will also generate a silent alarm. A
silent alarm will not trigger any bells or sirens, but the system will have to be disarmed.
[1] ON / [2] ON: Audible Alarm
In an armed system and a tamper wiring failure occurs on a zone, the control panel will follow the zone's Alarm Types setting (see
page 16). In a disarmed system, it functions the same as Trouble Only setting, except it will also generate an audible alarm.