User's Manual

Table Of Contents
PART 1: INTRODUCTION
1.1 FEATURES
Up to 15 fully programmable zones
Two completely independent partitions. Many of the features and options in the Spectra System can be independently set for each
partition such as event reporting, entry/exit delay, auto-arming and many more. All zones, the keyswitches and all user codes are
assigned to specific partitions, which makes this a true partitioned system.
Communication bus facilitates the adding, programming and monitoring of all expansion modules.
1 Installer Code and 48 User Codes (including: 1 System Master, 2 Masters, and 1 Duress)
2 on-board, fully programmable outputs (PGMs) and one 5A alarm relay
Simple, direct and logical programming
Event Call Direction: The Spectra 1759EX control panel events are divided into 5 groups of events. Each of these event groups can
be programmed with a separate dialing sequence.
Two 32-digit Central Station Telephone Numbers and one 32-digit Backup Telephone Number
Contact ID, Pager Format and many more High-Speed Communication Formats
"False Alarm Prevention" features such as: Intellizone, Auto Zone Shutdown, Beep on Exit Delay, Programmable Delay Before Alarm
Transmission, and Recent Closing Report
Regular Arming, Stay Arming, Instant Arming, Force Arming, One-Touch Arming, Auto-Arming, or Keyswitch Arming
256 Event Buffer with time stamp
Telephone Line Supervision
Keypad activated panic alarms
Compatible with Winload Security System Management Software for Windows®
1.2 SPECIFICATIONS
1.2.1 SPECTRA 1759EX CONTROL PANEL
AC Power: 16Vac transformer with minimum 20VA rating (Rec.: 40VA), 50 to 60Hz
Battery: 12Vdc, 4Ah/7Ah
Aux. Power:
+
600mA typical, 700mA maximum, fuseless shutdown @ 1.1A
Bell Output:
++
1A, fuseless shutdown @ 3A
PGM Outputs: PGM1 = 150mA low-current output, PGM2 = 2.5A high-current output
Alarm Relay: One form “C” relay rated @ 125V, 5A receptive load
Frequency: 433MHz or 868MHz
1.2.2 SPECTRA KEYPADS (1686H, 1686V, 1689 AND 1641)
Power input: Typically 9-16Vdc
1 standard keypad zone
On-board tamper switch (optional)
1686H and 1686V 10-Zone LED Keypad
Current consumption: 62 to 116mA
1689 16-Zone LED Keypad
Current consumption: 50 to 117mA
1641 32-Character LCD Keypad
Current consumption: 60 to 80mA
PGM: 1 with 50mA current limit
LCD: Super Twisted Nematic display (STN), Wide viewing angle, Backlight & Contrast
adjustable.
Approvals:
433MHz
868MHz
Specifications may change without prior notice
+
Cannot exceed 200mA for UL installations
++