User's Manual
Table Of Contents
- Table of Contents
- Part 1: Introduction
- Part 2: Installation
- Part 3: Programming Methods
- Part 5: Zone Programming
- Part 7: Arming and Disarming Options
- 7.1 Switch To Stay Arming
- 7.2 Stay Arming with Delay
- 7.3 Regular Arming switches to Force Arming (Not to be used with UL Installations)
- 7.4 Restrict Arming On Battery Fail
- 7.5 Restrict Arming On Tamper Failure
- 7.6 Timed Auto-Arming
- 7.7 No Movement Auto-Arming
- 7.8 Auto-Arming Options (Not to be used with UL installations)
- 7.9 One-Touch Arming (Not to be used with UL installations)
- 7.10 Exit Delay
- 7.11 Bell Squawk On Arm/Disarm With Keypad
- 7.12 Bell Squawk On Arm/disarm with Remote Control
- 7.13 No Exit Delay When Arming with Remote Control
- 7.14 No Exit Delay Beeps and No Bell Squawk When Stay Arming
- Part 8: Alarm Options
- Part 9: Reporting and Dialer settings
- 9.1 Reporting/Dialer (Enable/Disable)
- 9.2 Report Codes
- 9.3 Central Station Telephone Numbers
- 9.4 Partition Account Numbers
- 9.5 Reporting Formats
- 9.6 Pager Delay
- 9.7 Event Call Direction
- 9.8 Dialing Method
- 9.9 Pulse Ratio
- 9.10 Bell on Communication Failure
- 9.11 Dial Tone Delay
- 9.12 Maximum Dialing Attempts
- 9.13 Delay Between Dialing Attempts
- 9.14 Alternate Dial Option
- 9.15 Recent Close Delay
- 9.16 Auto Test Report
- 9.17 Power Failure Report Delay
- 9.18 Disarm Reporting Options
- 9.19 Zone Restore Report Options
- 9.20 Telephone Line Monitoring (TLM)
- Part 10: Programmable Outputs
- Part 11: System Settings
- 11.1 Hardware Reset
- 11.2 Installer Lock
- 11.3 Keypad Lockout Feature
- 11.4 Battery Charge Current
- 11.5 Partitioning
- 11.6 System Real-Time Clock
- 11.7 Clock Adjust
- 11.8 Keypad Tamper Supervision
- 11.9 Keypad Audible Trouble Warning
- 11.10 Confidential Mode
- 11.11 Installer Quick Functions Keys
- 11.12 PGM Modules Supervision
- 11.13 Printer Module Supervision
- 11.14 Zone Expansion Bus Module Supervision
- 11.15 Wireless Transmitter Low Battery Supervision
- 11.16 Wireless Transmitter Supervision Options
- 11.17 ReProgram All Expansion Modules
- Part 12: Settings for WinLoad Software
- Part 13: User Operation
- 13.1 Trouble Display
- 13.2 Programming Access Codes
- 13.3 Disarming & Deactivating an Alarm
- 13.4 Regular Arming
- 13.5 Stay Arming
- 13.6 Instant Arming
- 13.7 Force Arming (Not to be used with UL Installations)
- 13.8 Manual Bypass Programming
- 13.9 One-Touch Arming
- 13.10 Keyswitch Arming
- 13.11 Panic Alarms
- 13.12 Auto-Arming (Not to be used with UL installations)
- 13.13 Alarm Memory Display
- 13.14 Programming Chime Zones
- 13.15 Keypad Muting (Not to be used with UL installations)
- 13.16 Keypad Backlight (1686H and 1686V only)
- FCC WARNINGS
- Index
6.1.2 DELETING ASSIGNED WIRELESS TRANSMITTERS
Sections [601] to [608]
6.1.3 PROGRAMMING THE ZONES
The zones allocated to the wireless transmitters must be programmed. Refer to Zone Programming on page 14 for
more information.
6.2 VIEWING THE WIRELESS TRANSMITTER SIGNAL STRENGTH
Sections [631] to [638]
Once wireless transmitters have been installed and assigned to the Spectra 1759EX, the signal strength of each transmitter can
be verified in sections [631] to [638]. Each section represents the signal strength viewer for a specific device. For example,
section [631] is the viewer for the device in section [601] and section [638] is the viewer for the device in section [608]. Please
note that this feature only works with wireless transmitters assigned to an Expansion Input (zone) as described in section 6.1.1 on
page 20. A reading of 1 is the weakest and a reading of 8 is the strongest. An average reading of 3 and up is acceptable.
Sometimes moving the transmitter or control panel by a small amount will greatly increase the signal reception.
After entering the desired section, ignore the first reading as it will not be accurate.
You can also use a beep sequence feature to verify a transmitter’s signal strength. When you press a transmitter’s tamper switch,
beep tones emanating from all the keypads connected to the communication bus will advise you of the transmitter’s signal
strength.
This feature cannot be used with any remote controls assigned to the control panel.
6.3 SERIAL NUMBER DISPLAY
Section [630]
This feature will display the serial number of any wireless transmitter on any Spectra keypad.
How Do I Delete Assigned Wireless Transmitters?
1) Press the [ENTER] key.
2) Enter your [
INSTALLER CODE].
3) Enter the desired [
SECTION NUMBER] (from sections [601] to [608]).
4) Press the [0] key six times to clear the serial number.
How Do I View a Wireless Transmitter’s Signal Strength?
1) Press the [ENTER] key.
2) Enter your [
INSTALLER CODE].
3) Enter the desired [
SECTION NUMBER] (from sections [631] to [638]).
4) Press the transmitter’s tamper switch or open the corresponding zone.
5) On an LED keypad: The keypad will illuminate numbers 1 to 8.
On an LCD keypad: The keypad will display numbers from 1 to 8 on the screen. For example, the LCD screen below
shows a signal strength reading of 5.
How Do I Attain a Wireless Transmitter’s Signal Strength using the Beep Sequence?
1) Press the [ENTER] key.
2) Enter your [
INSTALLER CODE].
3) Enter the desired [
SECTION NUMBER] (from sections [631] to [638]).
4) Press the transmitter’s tamper switch or open the corresponding zone.
5) Listen for the beep tones:
If the signal strength is less than 3 = One beep
If the signal strength is between 3 and 6 = Two beeps
If the signal strength is greater than 6 = Three beeps
How Do I View a Transmitter’s Serial Number?
1) Press the [ENTER] key.
2) Enter your [
INSTALLER CODE].
3) Enter the section [630].
4) Press the [0] key six times to clear the serial number.