Data Sheet
PE IoT Engine
Datasheet
Document No. [DOC-DAT-0023-04] Date of last revision [04.03.2021]
Page 14 / 30
Table 8 – List of Switches
Name
Description
SW1
Soft RESET – Push the button to RESET the device
SW2
BOOT0 – Move the switch to the right to activate the bootloader
SW3
V_ADC – Move the switch to the right to supply external power to the ADC.
Move the switch to the left to enable VCC to supply power to the ADC.
SW4
VMAIN – Move the switch to the right to enable low power mode and bypass the protection diode
SW5
VBAT - Move the switch to the right to enable the PE IoT Engine to use externally supplied power
(such as from a battery).
Move the switch to the left to enable VCC to supply power to the VBAT pin
Figure 7: Top View with J18 Header and SW1, SW2, SW3, SW4, and SW5 Switches
J18 Header
SW4 Switch
SW3 Switch
SW2 Switch
SW5 Switch
SW1 Switch