Installation Manual
PE Smart Mini Gateway
Document No. [DOC-INS-0115-05] Date of last revision [31.05.2021]
Page 22 / 50
After executing those steps, you need to use your laptop to connect to the internal webserver of the Mini
Gateway. This can be accomplished by either joining the internal Wi-Fi access point of the Mini Gateway
or using an Ethernet cable to connect directly to the Ethernet 0 port. Refer to Figure 5 (above) to see the
location of Ethernet 0.
NOTE: If you join the Wi-Fi access point of the Mini Gateway,
the SSID is “PE-hotspot” and the password is “h0tst0PE”.
If, however, you connect an Ethernet cable to Ethernet 0, then
you need to modify your network settings to ensure that you
have a fixed/static IP address. The address needs to be
192.168.1.100 netmask 255.255.255.0 and gateway
192.168.1.10.
You now are able to login to the internal website of the Mini Gateway. To login, use your web browser to
navigate to the following URL:
hiip://192.168.1.10
NOTE: The default login is “admin” and the password is
“pwd_gwadmin_demo”.