Installation Manual

PE Smart Gateway Neptune US
Installation manual
Document No. [DOC-INS-0059-02] Date of last revision [23.11.2018]
Page 15 / 30
Please notice that power supply cable, I/O cable and Ethernet cable are not supplied along with the product, but
available as optional equipment.
Wirings technical specifications are listed below:
Wirings technical specifications
Item
Unit
Power supply cable
Poles No.
-
3
Section
mm
2
0.75 (min)
Length
mm
3000 (max)
Rated voltage
V
450/750
Mating
-
UTS6JC103S Souriau
Compliance
-
Compliant with local regulation
4.4.1 Power supply connector
A power supply cord with a minimum conductor section 0.75 mm
2
(AWG-18) suitable for outdoor use and
in compliance with relevant local and national regulations shall be used
Pinout of the power supply cable connector is pictured in Figure 11.
Figure 11 Pinout of the power supply cable, viewed from the connector side
Power supply cable wires description
Label
Function
1 (L)
Line/Phase input from AC mains power
2 (N)
Neutral input from AC mains power
Ground