PE Smart Gateway Neptune US Installation manual PE Smart Gateway Neptune US AR41004 US Installation manual Document No. [DOC-INS-0059-02] Date of last revision [23.11.
PE Smart Gateway Neptune US Installation manual Table of contents Product Description ................................................................................................................................... 3 Content List ................................................................................................................................................ 3 Warnings for installers and users ..................................................................................................
PE Smart Gateway Neptune US Installation manual Product Description PE Smart Gateway Neptune US is a key hardware element of Paradox Engineering’s PE Smart Urban Network platform for city environments. Refer to [PD_1] and [PD_2] for further product information. Content List The box contains the following items: Part Number Description Q.
PE Smart Gateway Neptune US Installation manual Warnings for installers and users The following instructions provide important precautions to safely install, use and maintain the product. Please read and follow them carefully before operating the unit: failure to comply may compromise people safety and/or damage the device, with serious consequences depending on circumstances.
PE Smart Gateway Neptune US Installation manual A power supply cord with a minimum conductor section 0.75 mm2 (AWG-18) suitable for outdoor use and compliant with relevant local and national regulations shall be used In the final installation, an external 20 A magneto-thermal switch must be installed as means of shortcircuit backup protection It is recommended to apply an adequate splicing tape in the final outdoor installation as specified at par. 4.3.3.1.
PE Smart Gateway Neptune US Installation manual Installation instructions 4.1 Grounding instructions The equipment must be grounded. PE Smart Gateway Neptune US is a Class I equipment provided with a grounded appliance inlet.
PE Smart Gateway Neptune US Installation manual 4.2 Dimensions Mechanical dimensions of PE Smart Gateway Neptune US are pictured in Figure 3. Figure 3 Dimensions of PE Smart Gateway Neptune US Document No. [DOC-INS-0059-02] Date of last revision [23.11.
PE Smart Gateway Neptune US Installation manual 4.3 Mounting 4.3.1 Standard mounting brackets PE Smart Gateway Neptune US can be mounted on a flat surface or a pole. Figure 4 pictures a typical installation. Please consider the product can be mounted on poles with different diameters. Relevant parameters for installation Item Unit Value m 2000 Above the sea level Maximum pole diameter mm 74 ± 1 See par. 4.3.2 for alternative mounting brackets M5 screws torque force Nm 5.2 ± 0.
PE Smart Gateway Neptune US Installation manual 4.3.2 Alternative mounting brackets Upon request, Paradox Engineering can provide an alternative set of mounting brackets to install the product on larger poles, as pictured in Figure 5. Figure 5 Alternative mounting set (example) Document No. [DOC-INS-0059-02] Date of last revision [23.11.
PE Smart Gateway Neptune US Installation manual 4.3.3 Antenna mounting Mounting all antennas before powering the product is highly recommended to avoid product configuration issues PE Smart Gateway Neptune US antenna connectors are pictured in Figure 6. PORT 4 SMA Connector NB Sub-GHz PORT 3 N Connector 2.4 / 5.x GHz WiFi Antenna PORT 2 N Connector 2.4 / 5.x GHz WiFi Antenna PORT 1 N Connector 5.
PE Smart Gateway Neptune US Installation manual PORT 2 PORT 3 PORT 4 PORT 1 Figure 7 PE Smart Gateway Neptune US antenna mounting. Example with all broadband antennas ANT-OUT-0021 and narrowband antenna ANT-OUT-0020 Document No. [DOC-INS-0059-02] Date of last revision [23.11.
PE Smart Gateway Neptune US Installation manual 4.3.3.1 Application of the voltage splicing tape The application of the voltage splicing tape is highly recommended for final outdoor installations The voltage splice tape shall be applied after that all antennas are mounted on PE Smart Gateway Neptune US. Please follow these instructions to properly apply the tape. Cut the splicing tape at 20 cm and remove the protective film Apply the tape to cover all the metallic bottom part of all antenna connectors.
PE Smart Gateway Neptune US Installation manual 4.3.3.2 Use of RF extension cord for antenna mounting In case of use of RF extension cords, these shall be safely locked on the pole or wall via cable ties or other adequate means, depending on field installation. Figure 8 pictures a typical method to fix antenna cables to the pole by using a cable tie Figure 8 Representative illustration of RF extension cords mounted on a pole Document No. [DOC-INS-0059-02] Date of last revision [23.11.
PE Smart Gateway Neptune US Installation manual 4.4 Wirings PE Smart Gateway Neptune US input connectors and wiring scheme are pictured in Figure 9 and Figure 10. PWR Power Supply Connector I/O Connector ETH Ethernet RJ45 Connector Figure 9 PE Smart Gateway Neptune US connectors BroadBand 2.4 / 5.x GHz WiFi Antennas NarrowBand Sub-GHz Antenna BroadBand 5.x GHz WiFi Antenna Figure 10 PE Smart Gateway Neptune US wiring scheme Document No. [DOC-INS-0059-02] Date of last revision [23.11.
PE Smart Gateway Neptune US Installation manual Please notice that power supply cable, I/O cable and Ethernet cable are not supplied along with the product, but available as optional equipment. Wirings technical specifications are listed below: Wirings technical specifications Item Unit Power supply cable - 3 Section mm2 0.75 (min) Length mm 3000 (max) Rated voltage V 450/750 Mating - UTS6JC103S Souriau Compliance - Compliant with local regulation Poles No. 4.4.
PE Smart Gateway Neptune US Installation manual 4.4.1.1 Power connector mating procedure The pictures below provide step-by-step instructions on how to properly mate the power plug and receptacle in order to avoid contacts damage. Identify the primary key of each connector Align connectors’ primary key and insert it During coupling, be sure to insert the connector in the correct position Turn clock-wise coupling ring until the position is locked Document No.
PE Smart Gateway Neptune US Installation manual 4.4.2 I/O connector If the I/O cable is unused, cover the port with the plug/cap to ensure product IP rating The I/O cable mates with the I/O connector providing 1 opto-isolated dry contact input and 1 analog input. Figure 12 Pinouts of the I/O connector, viewed from the connector side I/O cable wires description Label Color A Blue B Function Ratings Dry Contact, External input (+) DC 5.
PE Smart Gateway Neptune US Installation manual 4.4.3 Ethernet connector If the Ethernet cable is unused, cover the port with the plug/cap to ensure product IP rating Figure 13 Pinout of the Ethernet connector Document No. [DOC-INS-0059-02] Date of last revision [23.11.
PE Smart Gateway Neptune US Installation manual Product configuration PE Smart Gateway Neptune US must be connected to the customer network via Ethernet port, configuring the IP address to match local addressing plan. Three different network devices are embedded on PE Smart Gateway Neptune US, and each of them is reachable from the external Ethernet port: • • • 5.
PE Smart Gateway Neptune US Installation manual If CMS’ IP is different from default setting, please modify it accordingly in the AMI Settings section of GW Manager by changing the “ServerAddr” IP. Please ensure to correctly configure your network firewall to allow bidirectional communication over the TCP port range. 5.3 Gateway to PE PE Smart Gateway Neptune US will attempt to establish a VPN link to Paradox Engineering network through TCP port 21194.
PE Smart Gateway Neptune US Installation manual 5.4 NTP configuration PE Smart Gateway Neptune US should have time configured by an NTP server. The product is pre-configured to use public NTP servers. If public NTP servers (UDP port 123) are filtered by your firewall, or if a DNS server is not available, other NTP servers can be configured under AMI Settings/NTP.
PE Smart Gateway Neptune US Installation manual 5.5 Timezone configuration To set timezone, click on the “Timezone” page, select the desired option from the drop-down menu and click on “Continue” to confirm. Based on your selected timezone, further options may be requested. Please select accordingly and click on “Continue” to confirm and complete configuration. 5.6 Other configurations Please DO NOT modify any other setting, unless receiving specific instructions by Paradox Engineering. Document No.
PE Smart Gateway Neptune US Installation manual Packing A representative packing scheme for PE Smart Gateway Neptune US is pictured in Figure 14. Figure 14 Packing scheme Document No. [DOC-INS-0059-02] Date of last revision [23.11.
PE Smart Gateway Neptune US Installation manual Label Figure 15 PE Smart Gateway Neptune US label Label icons description Symbol Description MinebeaMitsumi trademark FCC compliance UL listing mark RoHS compliance Waste Electrical and Electronic Equipment Directive (WEEE Directive) Refer to the installation manual Document No. [DOC-INS-0059-02] Date of last revision [23.11.
PE Smart Gateway Neptune US Installation manual Maximum Permissible Exposure (MPE) limits PE Smart Gateway Neptune US is compliant to Maximum Permissible Exposure (MPE) limits. The following tables summarize the results of the calculations carried out assuming no co-location or operation in conjunction with any other antenna or transmitter. It is also indicated the minimum distance to keep between antennas and the public: Document No. [DOC-INS-0059-02] Date of last revision [23.11.
PE Smart Gateway Neptune US Installation manual Notice Changes or modifications made to this equipment not expressly approved by Paradox Engineering may void the user’s authority to operate this equipment. Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
PE Smart Gateway Neptune US Installation manual Certification Directives Directive 2011/65/EU Title Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment Standards Standard UL 62368-1 FCC 47 CFR part 15 9.1 Title Audio/video, information and communication technology equipment - Part 1: Safety requirements FCC 47 CFR Part 15, Subpart C - Intentional Radiators Approval and compliance Approval Approval Issued by Certificate No.
PE Smart Gateway Neptune US Installation manual Ordering codes Ordering codes Product name Code PE Smart Gateway Neptune US AR41004 US Optional power supply cable2 CAB-PWR-0019-01 Optional signal cable3 CAB-SIG-0026 Alternative mounting brackets4 MEC-OTH-0036 Optional outdoor directional panel antenna 5.15-5.875 GHz, 18 dBi gain, Linear V/H Polarity, N Type ANT-OUT-0025 Optional outdoor directional panel antenna (sector) 4.9-5.
PE Smart Gateway Neptune US Installation manual References / Related documents 12.1 General Documents Item Document Number Document Title/Description [GD_1] 178919 D01 FCC Permissive Change Policy 12.2 Paradox Engineering Documents Item Document Number Document Title/Description [PD_1] DOC-DAT-0007 PE Smart Gateway Neptune US Datasheet [PD_2] DOC-INS-0065 PE Smart Gateway Neptune US User manual 12.
PE Smart Gateway Neptune US Installation manual Revision History Revisio n Document No. 00 DOC-INS-0059-00 01 DOC-INS-0059-01 02 DOC-INS-0059-02 Created by Verified by Approved by M. Merletti /R. Palmiero L. Grillo C. Bernocco R. Palmiero F. Bottazzi L. Grillo R. Palmiero F. Bottazzi L. Grillo Date Description 27.03.2018 First document release 12.10.2018 Updated the MPE table and FCC notices. Product label revised according FCC certification. 23.11.