Universal Remote User Manual
RCP2-1000 RM Remote Controller Operations Manual  203987 Rev A  9 
1.3.2 Electrical Discharge Hazards 
A spark can not only create ESD reliability problems, it can also cause serious safety 
hazards. The following precautions should be taken when there is a risk of electrical 
discharge: 
•  Follow all ESD guidelines. 
•  Remove all flammable material and solvents from the area. 
•  All probes and tools that contact the equipment should be properly insulated 
to prevent electrical discharge. 
•  The work area should be secure and clear from non-essential items. 
•  Operators should never work alone on high voltage devices. There should 
always be another person present in the same work area to assist in the 
event of an emergency. 
•  Operators should be familiar with procedures to employ in the event of an 
emergency, i.e. remove all power, CPR, etc. 
1.4 Specification Summary 
Table 1-1 contains a summary of the specifications of the RCP2-1000 RM redundant 
system controller. 
Configurations RCP2-1000 RM; 1:1 Redundant System 
Switch Time  Fault Detection, 20-50 msec 
Total switchover, 100 msec maximum 
Switch Drive  26 VDC @ 4 amps 
Alarm Input  Closure to Ground, (Ground = OK / Open = Fault) 
Parallel I/O 
 Status Outputs 
 Control Inputs 
Form C Relay Contacts (10 sets) 
Contact Closure to Ground 
Table 1-1: RCP2-1000 RM Specification Summary 
AC Input Power  85-265 VAC, 47-63 Hz, 1 A max, > 0.93 power factor 
Mechanical Dimensions  1.75 in. H x 19 in. W x 13.3 in. D [1 RU] 
(89 mm H x 483 mm W x 338 mm D) 
Weight  5 lb (2.3 kg) 
Environmental Temperature  0 - 50 
o
C 