Universal Remote User Manual
RCP2-1000 RM Remote Controller Operations Manual  203987 Rev A  23 
If the HPA controller card can not reliably communicate with an SSPA module, that 
module will be declared faulted. This type of fault will not affect the HPA overall      
summary fault state, because the controller card has the ability to track RF module 
faults independently. 
3.2.2 Panel Communication Setup Sub-Menu 
This menu allows the user to select the parameters for communication between the 
SSPA and any remote monitor and control station. 
3.2.2.1 Protocol 
Allows the user to select the serial protocol. Available protocols include: 
  a) Normal (as described in Section 5) 
  b) Terminal (as described in Section 6) 
3.2.2.2 Baud Rate 
Selects the desired baud rate for serial communication. Available baud rates include 
2400, 4800, 9600, 19200 and 38400. The factory default Baud Rate is 9600. 
3.2.2.3 System Address 
Sets the network address of the controller if used on a RS-485 network. Choose 1-255. 
The factory default address is 0. 
Note:  Changes in serial communication settings from the front panel are effec-
tive immediately. Changes to these parameters from serial interface require that 
the unit be reset in order to take effect. The units can be reset either by cycling 
power to the unit or by issuing a reset command from the front panel. 
3.2.2.4 Interface 
Toggles between RS232 or RS485 communication. 
3.2.3 SSPA Setup Sub-Menu 
This menu allows the user to select the attenuation, mute status, redundancy mode, 
and fault setup of the connected SSPA. 
3.2.3.1 Attenuation 
Allows user to set the desired attenuation between 0 and 20.0 dB. 
3.2.3.2 Mute 
Allows user to Set or Clear the Mute status for the unit. 