System Instruction
1. REPLACE SMARTCANISTER™: If the SmartCanister™ is removed during
dispensing, the system will automatically pause dispensing and display this
error message. Replace the SmartCanister™ on the Base Unit and press the
SPOON button to continue dispensing. Or press the BACK button to cancel.
2. REPLACE BOWL: If the bowl is removed during dispensing, the system will
automatically pause dispensing and display this error message. Replace the
bowl on the Base Unit scale and press the SPOON button to continue
dispensing. Or, press the BACK button to cancel.
3. *INCORRECT CANISTER (when following a recipe from the Chefling APP):
This message will appear when the PANTRYCHIC™ system is using
Bluetooth
Ⓡ
connectivity to follow a recipe via the Chefling app. If the wrong
ingredient SmartCanister™ is placed on the Base Unit this message appears.
4. DISPENSING STOPPED: If the system detects no weight change during the
dispensing process, it first attempts to clear a jam in the canister. If it still
detects no weight change, the system will automatically pause dispensing
and display this error message. There are several possible causes of this
error, so check each of the following:
a. The SmartCanister™ is empty or low on ingredient. Refill the
SmartCanister™ with more of the same ingredient and press the SPOON
button to continue dispensing. Or, remove the SmartCanister™ from the
base unit, gently move the SmartCanister™ around to bring the ingredients
towards the center auger, reseat the lid and press the SPOON button to
continue dispensing.
b. The SmartCanister™ lid is not securely attached. Press down on the lid to
ensure it is completely closed. For safety, the system will not operate if the
lid is loose or missing on a large SmartCanister™. Press the SPOON button to
continue dispensing.
c. The SmartCanister™ is jammed. Try each of the following steps:
1. Remove the SmartCanister™ from the Base Unit. Gently shake
the canister and reseat it on the Base Unit. Press the SPOON
button to continue dispensing. If the error does not clear:
2. Remove the SmartCanister™ from the base unit and take off the
lid. With a spoon or other utensil, gently move ingredient away
from the center auger and its lid. Replace the cover and reseat
the SmartCanister™ on the Base Unit. Press the SPOON button
to continue dispensing. If the error still does not clear:
3. Remove the SmartCanister™ from the Base Unit and take off the
lid. Manually rotate the center auger and remove ingredient
that is causing the jam. Replace the lid and reseat the
SmartCanister™ on the base unit. Press the SPOON button to