OPERATOR’S MANUAL Model 150 WARNING Read and become familiar with this manual BEFORE operating unit. Before operating this equipment, thoroughly read this set of instructions, make sure you understand them, and only then follow the step-by-step directions. Failure to do so could result in serious property damage and / or serious bodily injury.
To our valued customer, Thank you for choosing a product by Manufacturing Solutions. We are pleased that we are able to provide equipment to make your work easier. Our efforts are focused on producing the finest quality equipment of which we are capable. We make sure to spend extra time and effort on our design and production in order to reduce your time and effort spent using the product. We take pride in providing the best for our customers.
CONTENTS Warning / Instructional Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1 Cable Inspections/Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2 Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 3 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 4 Tools . . . . . . . . . . . .
WARNING Read and follow these warnings and the instructions that follow. Failure to do so could result in serious property damage and/or serious bodily injury. Decal Warnings: Please note these warning decals located on the HANGPRO™. These decals do not replace the necessity of reading and understanding the instructions within this operators manual. Pinch Point Cau�on When Assembling your HangPro™ Insert BOTH 3’ x 3/8” bolts and 3/8” Nylock nuts.
ASME Standards for wire rope (cable) inspection and replacement Reprinted with permission from ASME B30.19 Cableways The following is intended as a helpful guide to the general topic of inspection and replacement of wire rope (cable). It is not intended to be an exhaustive treatment of the topic. Frequent inspection (at least daily) by a competent person and prompt replacement of any cable that shows any sign of wear is the responsibility of the owner and the operator of the PANELLIFT® Drywall Lift.
CARE AND MAINTENANCE Inspect cable FREQUENTLY. (At least daily and before each use) Replace at the first sign of wear. Occasionally oil the cable sheaves and caster bearings. Store the HANGPRO™ Drywall Lift in a dry place. Apply household paraffin to the surfaces of the telescoping sections, for smoother action. Take reasonable care to avoid damaging the HANGPRO™ Drywall Lift when transporting it. Do not hammer on any members or components of the HANGPRO™ Drywall Lift.
COMPONENTS A C B F E A: B: C: D: D Square Cradle Upper Mast Wheel Leg Lower Mast G E: Winch F: Cable G: Cable Keeper TOOLS REQUIRED • ADJUSTABLE WRENCH • 3/8” WRENCH • 9/16” WRENCH • 5/8” WRENCH • FLATHEAD SCREWDRIVER • 7/16 WRENCH 4
ASSEMBLY 1 2 3 4 1. Place the Lower Mast Assembly face down on the floor as shown. 2. Attach the Wheel Leg Assembly to the Lower Mast Assembly with the warning decal facing the top of the mast section. Insert the tapered tabs into the slots as shown. 3. Secure the Wheel Leg Assembly to the Lower Mast Assembly with two 3” x 3/8” Bolts and 3/8” Nylock nuts. Tighten with two 9/16” wrenches, or adjustable wrench. 4. Stand the assembled Lower Mast and Wheel Leg upright. 5 6a 6 7 5.
ASSEMBLY CONTINUED 8 9 10 11 8. Place the winch on the mounting plate at the back of the HANGPRO™, with the gear side of the winch near the mast. 9. Insert three 7/8” x 3/8” bolts down through the winch base and mounting plate and attach the 3/8” Nylock nuts from beneath. Tighten with two 9/16” wrenches or adjustable wrench. 10. Attach the Winch Handle by pushing in and turning clockwise. 11. Secure the handle with the bolt, washer, spacer and spring provided with the winch as shown.
ASSEMBLY CONTINUED 14a 15 16 14a. The carriage bolt head must be positioned through a square hole on the inside of the winch spool with the washer and nut on the outside of the spool wall. Tighten with 3/8” wrench. 15. Attach the Cable Keeper to the top of the Upper Mast. 16. Tighten the Cable Keeper with a 5/8 wrench and an adjustable wrench so the nut is firmly secured to the bolt. DO NOT OVERTIGHTEN! THE SHEAVE MUST BE ABLE TO TURN FREELY.
OPERATION PREPARING DRYWALL PANELS Drywall panels are typically stocked leaning horizontally in small stacks against walls. When the drywall bundle is opened the first panel has to be flipped around so the good side of the panel is facing out. LOADING A PANEL Center the lift on the panel and position about an inch away from the panel. Lower the cradle to the floor. Lift one end of the panel onto the cradle support hooks. Lean the panel back against the cradle frame.
OPERATION CONTINUED USING THE FRONT WHEELS FOR PRECISE POSITIONING When the lift is leaned forward onto the front wheels it can be moved side-to-side for the precise positioning before or after lifting the panel. REMOVING THE LIFT AFTER PANEL IS SECURED Secure the panel to the wall. Turn the winch handle counter clockwise to lower the cradle before moving the lift. TRANSPORTING THROUGH A DOORWAY OR HALLWAY Load a panel as described on prior page.
PARTS INDEX Part Number: 150-58 150-59 150-51 150-60 150-61 150-57 150-54 150-52 150-50 Lower Mast Assembly w/Fasteners 150-51 Upper Mast Assembly w/Fasteners 150-52 Square Cradle w/ Cable Fasteners 150-53 Wheel Leg Assembly w/Fasteners 150-54 Winch w/Fasteners 150-55 3” Wheel w/Fasteners 150-56 8” Wheel w/Fasteners 150-57 Cable w/Fasteners 150-58 Cable Sheave w/Fasteners 150-59 Cable Keeper w/Fasteners 150-60 Cable Roller w/Fasteners 150-61 Horizontal Handle Cover (pair) 150-50
SAFETY INFORMATION This product contains trace amounts of the following items which are known to cause. These chemicals are not hazerdous under product’s intended use. Please review CAS# for more informa�on.
WARRANTY PARAGON PRO MANUFACTURING SOLUTIONS INC LIMITED WARRANTY TELPRO INC products manufactured by PARAGON PRO MANUFACTURING SOLUTIONS INC are warranted to be free from defects in material and workmanship under normal use for one year from date of purchase. NOTE: The following components of the PANELLIFT® Model 439 Drywall Lift are warranted to be free from defects in material and workmanship under normal use for three years from date of purchase.
Q uestions about assembly? Can’t find a part? Need some other help? Call us: 1.800.448.0822 701.775.