Installation Manual
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2014
V00028NW
Page 8 of 12
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2014
Removable Gland Plate
The Gland Plate, located on the bottom of the enclosure, is removable for machining to accept bulkhead connectors or compression
fittings. Remove (12) screws and (12) flat washers on the bottom of the enclosure to remove plate from the enclosure. Accommoda-
tions for incoming conduit have been supplied on the enclosure. A 1/2” conduit plug is installed in the recommended incoming
power location. Recommend installation of IP66 rated conduit fittings that comply with the IEC codes that are applicable to the
intended application. When reinstalling the gland plate, ensure the screws are tightened until the gland plate flanges make contact
with the enclosure surface.
Gland plate
Plug